Red Light; Meters Section; Mix Meter Follow Mon Source; Peak Mode Select - Solid State Logic ORIGIN User Manual

Hide thumbs Also See for ORIGIN:
Table of Contents

Advertisement

NOTE : If the IN FRONT BALANCE control is left fully clockwise (i.e. an all mix bus balance) then it may appear that
the AFL/Solo function isn't working as there is no AFL signal feeding the monitoring, (i.e. you're only listening to the
mix bus signal, i.e. no AFL/Solo signal)!

RED LIGHT

The RED LIGHT function closes a relay on the DB-9 UTILITY connector on the rear panel of the console. Typically this is used for
a Record Light for the studio, to indicate not to disturb the recording area. If nothing is connected to the UTILITY connector, then
this switch has no function (other than illuminating the associated red front panel LED!). The RED LIGHT relay switch closure will
change state when the console goes to SLEEP. This could be used to switch off other studio equipment, or to signal externally that
the console is in sleep mode, if the RED LIGHT function is not required.

METERS Section

MIX METER FOLLOW MON SOURCE

The MIX meter typically shows the level of the main stereo Mix bus. Pressing the MIX METER FOLLOW MON
SOURCE switch switches the MIX meter to follow the selection on the MON SOURCE section. This is useful
to meter, or calibrate an external source connected to one of the four External Source selectors.
L
R
dBu
24

PEAK MODE SELECT

23
22
21
The meters in ORIGIN are fast detecting 'peak' meters. These meters have some options for displaying peaks
20
and the PEAK MODE SELECT switch cycles around these modes with repeated pressing. The options are:
19
18
No Peak Hold. The meter displays instantaneous peak values only
-
15
12
First Press - 1 second Peak Hold. Peak level LED stays illuminated for approximately 1 second and
-
9
then automatically resets. This mode can be identified when selected by the red +24dBu LEDs
6
4
illuminating for approx. 1 second and then falling to the current metered level.
0
4
Second Press - 3 second Peak Hold. Peak level LED stays illuminated for approximately 3 seconds
-
6
and then automatically resets. This mode can be identified when selected by the red +24dBu LEDs
8
10
illuminating for approx. 3 seconds and then falling to the current metered level.
12
15
Third Press - Permanent Peak Hold. The LED indicating Peak level achieved stays illuminated
-
18
indefinitely and can be reset using the PEAK CLEAR function (see below). This mode can be identified
21
25
when selected by the red +24dBu LEDs rippling across 8 channel sections.
28
Fourth Press - returns to the no Peak Hold state.
-
32
11
12
The console will remember the setting when powered off, so the start state for the first press may be offset
F
(e.g. if in 1 second Peak hold when powered off, the next press after power on will be 3 second.)

PEAK CLEAR

Resets the captured Peak level (and indication) for all meters when permanent Peak Hold mode is selected (see PEAK MODE
SELECT above).
ORIGIN User Guide
L
R
dBu
24
23
22
21
20
19
18
15
12
9
6
4
0
4
6
8
10
12
15
18
21
25
28
32
13
14
G
L
R
dBu
24
23
22
21
20
19
18
15
12
9
6
4
0
4
6
8
10
12
15
18
21
25
28
32
15
16
H
Origin Master Section
L
R
dBu
24
23
22
21
20
19
18
17
16
15
14
12
10
8
6
4
0
4
6
8
10
12
14
16
18
20
22
24
26
30
35
40
MIX
31

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents