Technical parameter GSM: 850/900/1800/1900MHz GPRS: Class12,TCP/IP Working Voltage: 9~90V Working Current: ≈22mA (12vDC) Working Current: ≈12mA (24vDC) GPS Fixed Time: Cold start≈38s(Open sky) Warm start≈28s Hot start≈2s(Open sky) GPS Precision: 10m(2D RM) Working Temperature: -20k~+70k Working Humidity: 20%~80%RH 10).Measurement :L64.5mm*W23.0mm*H12.5mm Installation Please read the instructions in detail;...
Page 3
Switch device must be switched to "ON" whenusing, as shown. This time can be connected to the external 9-90V power supply. Note: because the charging voltage of the electric vehicle is unstable, the instantaneous voltage is too high, and the device is used prudently on the electric vehicle above 70 volts.
Page 4
Finally, the terminal will be fixed in the car's concealed position with two sided glue or tie line. Note: the terminal SIM card cannot be on backward. Terminal SIM card needs to open GPRS function, and ensure that the terminal SIM card has tariff. If your SIM is open, you need to input PIN code.
Page 5
GPS antenna. When installing, we should ensure that the GPS faces upwards (up to the sky), and there are no metal objects above it. Note: if the windshield is glued with metal insulation or heating layer, it will reduce the GPS reception signal and cause the GPS work to be out of order.
Page 7
terminal work opening: after the terminal is connected to the power, please pay attention to whether the SIM card has been inserted, if the SIM card is not inserted, please dial the switch to the OFF position first, then the external power is disconnected, and then the SIM card is inserted.
User instruction 1. CENTER Text Parameter Sample command CENTER,A,13500135 CENTER,A,nu 000# mber# CENTER,D# CENTER,D# 1)center number can be used to send short message instructions to restore the Description Description factory settings 2)the central number is also the function of SMS and telephone reception.
Page 9
3. VIBRATION 3. VIBRATION Text Text Parameter Parameter Sample Sample command command 1)VIBRATION,2,3# 1)VIBRATION,2,3# VIBRATION,level VIBRATION,level Format Format 2)VIBRATION,2# 2)VIBRATION,2# [,alarming way]# [,alarming way]# The sensitivity value of the vibration is from 1 The sensitivity value of the vibration is from 1 to 5 1is the most sensitive and o is close.
Page 10
6. RELAY 6. RELAY Text Text Parameter Parameter Sample Sample command command RELAY,1# cut off oil RELAY,1# cut off oil Parameter1 Parameter1 RELAY,1# RELAY,1# 1) REL AY control the start and closeness of 1) REL AY control the start and closeness of the relay,in order to control the circle the relay,in order to control the circle 2) Only the center number can operate.
Page 11
8. FEE 8. FEE Command Command Parameter Parameter Sample Sample FEE,10010,102# FEE,10010,102# FEE,Query FEE,Query Format Format FEE,10086,101# FEE,10086,101# number,contents# number,contents# This instruction is used to query the current This instruction is used to query the current calls status of the device SIM card Query calls status of the device SIM card Query number: SIM is the operator of the query number: SIM is the operator of the query...
name and password. Enter the service platform web site in your computer browser address bar, fill in the access account number and password, and then point to the service platform. Service platform function use operation please get "service platform operation guide" to your dealer. Trouble shooting The device is not online or offline on the web platform...
Page 13
3. VIBRATION 3. VIBRATION Text Text Parameter Parameter Sample Sample command command 1)VIBRATION,2,3# 1)VIBRATION,2,3# VIBRATION,level VIBRATION,level Format Format 2)VIBRATION,2# 2)VIBRATION,2# [,alarming way]# [,alarming way]# The sensitivity value of the vibration is from 1 The sensitivity value of the vibration is from 1 to 5 1is the most sensitive and o is close.
Page 14
6. RELAY 6. RELAY Text Text Parameter Parameter Sample Sample command command RELAY,1# cut off oil RELAY,1# cut off oil Parameter1 Parameter1 RELAY,1# RELAY,1# 1) REL AY control the start and closeness of 1) REL AY control the start and closeness of the relay,in order to control the circle the relay,in order to control the circle 2) Only the center number can operate.
Page 15
8. FEE 8. FEE Command Command Parameter Parameter Sample Sample FEE,10010,102# FEE,10010,102# FEE,Query FEE,Query Format Format FEE,10086,101# FEE,10086,101# number,contents# number,contents# This instruction is used to query the current This instruction is used to query the current calls status of the device SIM card Query calls status of the device SIM card Query number: SIM is the operator of the query number: SIM is the operator of the query...
Page 16
name and password. Enter the service platform web site in your computer browser address bar, fill in the access account number and password, and then point to the service platform. Service platform function use operation please get "service platform operation guide" to your dealer. Trouble shooting The device is not online or offline on the web platform...
please recharge it.If you can connect to the device when calling,and hear a beep. Du, du. noise the SIM card is installed correctly and has deposited and please check wi th your operator for GPRS function. Yo u also can check by searching the internet on your mobile phone.
Page 18
Warranty card Warranty card Maintenance record Maintenance record Maintenance shop Maintenance shop Sending date Sending date Fault description Fault description Maintenance situation Maintenance situation IMEI number IMEI number Maintenance Maintenance person person Maintenance record Maintenance record Maintenance shop Maintenance shop Sending date Sending date Fault description...