Current And Power Table With Gb 031-107; Lifting Motor - Gaggenau VL051-107 Repair Instruction

Table of Contents

Advertisement

At the outputs L1, L2 for the blower only 0 or 230V can be measured
against N.
The individual speeds are generated by upstream capacitors and
resistors. See table
Output L1
Off and pipe
0
retracted
Basic setting
230 V
Pipe extended
Setting 1
0
Setting 2
230 V
Setting 3
0
4.3

Current and power table with GB 031-107

The measured values may differ due to fluctuating mains.
The following values were measured at 228 V
Current I in A
Off
Basic setting
Setting 1
Setting 2
Setting 3
142_58300000122107_ara_en_b.doc – 02.02.09
Output L2
Circuit
0
---
12 µF + 8 µF
0
+ 2.7 KΩ
230 V
8 µF + 2.7 KΩ
0
12 µF
230 V
Without circuit
Power P in W
0
0
0.55
49
0.78
105
0.90
165
0.86
195
4.4

Lifting motor

The lifting motor is a direct-voltage motor 24 V DC.