Item
Rods, links, and wires in linkage shall be free
of deformation or damage.
Linkage
Connections shall be free of looseness,
excessive play, or missing cotter pins.
Shall be free of cracks, deformation, or
Chassis
corrosion.
Fastening bolts or nuts shall not be loose or
Frame
missing.
Shall be free of cracks or deformation.
Body Panels
Fastening bolts or nuts shall not be loose or
missing.
Loading deck shall raise and lower smoothly.
Panels shall slide and open smoothly and
can be locked in place securely.
Shall be free of cracks, deformation, or
Loading Deck
corrosion.
Fastening bolts or nuts shall not be loose or
missing.
Safety Lock
Safety lock plate shall be free of any
Plate
deformation.
Warning labels and instruction plates shall be
Labels
clean, legible, and free of damage.
Hydraulic fluid shall be clean and at correct
level.
No leaks shall be found in or around
hydraulic package.
Fastening bolts and nuts shall not be loose
or missing.
Breather shall not be clogged.
There shall be no leaks in pipes, hoses,
Hydraulic
joints, or seals.
No irregular vibration, noise, or heat shall
Package
be observed when hydraulic package is in
operation.
Amount and pressure of discharge under
load shall be within the standard range
specified by the manufacturer.
*this may be skipped if irregular vibration,
noise, or heat described above is not
observed.
Maintenance
Description
-31-
Schedule
Note
√ √ √
√ √ √
√ √
√ √
√ √
√ √
√ √
√ √
√ √
√ √
√ √
√ √ √
Inspecting/Changing:
√ √
Page 44
√ √
√ √
√ √