Page 12
■ ■ ■ ■ Countermeasures If any abnormality is found, perform checks according to the following list. If the abnormality cannot be eliminated, contact your SMC representative. Warning Discharge fluids from the pump. Eliminate the residual fluids, and thoroughly clean the product with pure water or air. Do not disassemble the product.
Page 13
Problem Possible causes Countermeasures - Dispense volume adjusting screw incorrectly set. - Adjust dispense volume screw until correct dispense obtained. - Excessive fluid viscosity. - Use fluid of the recommended viscosity. - Operating frequency is too high. - The frequency should be set at or below the maximum operating frequency. - Piping diameter is too small.
Page 14
Problem Possible causes Countermeasures - Intrusion of air from the suction (IN) side. . - Check the piping on the suction (IN) side. 5) Leakage of fluids from pump connections. - Sealing failure on the suction (IN) side or dispense (OUT) side. - Check sealing of the piping.