Installation and operation
Power supply connection
Verify if technical data of the appliance (see rating plate) correspond with the
local electric power grid specification.
Connect the appliance to a single, properly grounded mains socket with
protective contact. Do not connect the appliance to a multi-socket.
The power cord should be laid in a way preventing anyone from threading on it
or tripping against it.
Do not use the appliance with an external timer or remote control.
Water connection
For the water supply, the appliance comes with a factory-installed water tank.
Should such a need arise, the appliance can be connected to mains piping.
In order to utilise the connection, consider the following information:
– max. input water pressure is 3 bar
– min. input water pressure is 1 bar
Important Indication:
Starting with water hardness of 5° dH (German degrees), a water softening
device should be installed. We recommend the following products from
our range:
– Water filtering system for coffee makers, art. No. 109881
– Water softening device, WEH1350, art. No. 109878
190052