SECTION 6 - ACCESSORIES

Accessory Ratings

Spec.
Rated Output
120 Volts ±10%
27 A @ 91 VDC @ 20%
(20 A)
Duty Cycle
120 Volts ±10%
20 A @ 88 VDC @ 35%
(15 A)
Duty Cycle
240 Volts ±10%
27 A @ 91 VDC @ 35%
(27 A)
Duty Cycle
* While idling.

Generator Output

Engine Speed of 1800 rpm +/- 10%.
ANSI Specifications:
• 3-phase: 240 V, 60 Hz, 7.5 kW
• 1-phase: 240 V/120 V, 60 Hz, 6 kW
CE Specifications:
• 3-phase: 400 V, 50 Hz, 7.5 kW
• 1-phase: 220 V, 50 Hz, 6 kW
6-6
Amperes Input @
Rated Output, 60
kVa/kW
Hz, 1-Phase
28.8 max;
3.4 kVa
0.30 *
3.2 kW
20.6 max;
2.5 kVa
0.30 *
2.3 kW
13.9 max;
3.3 kVa
0.13 *
3.0 kW
Plasma Gas Flow/
Plasma Gas
Pressure
4.5 cfm
Air or Nitrogen Only
(129 L/Min)
@ 90 - 120 psi
@ 60 psi
(621 - 827 kPa)
(414 kPa)

Preparation and Inspection

• Connect ground clamp to metal being cut.
• Ensure there is a good ground connection.

Operation

Start the engine, turn on the generator, then turn on the plasma
cutter.
See the Miller Plasma Cutter Owner's Manual (PN 3128420) for
more information.
Rated Cutting
Max. OCV
Capacity @ 10 IPM
3/8 in
400 VDC
(10 mm)
31215030

Advertisement