7) Additional information

Programming, personalisation and how to look for and deal with faults on the RUN will be dealt with in this chapter.

7.1) Programming keys

The RUN control unit feature three keys that can be used to command the control unit
both during tests and programming:
Open
The "OPEN" key enables the user to control the opening of the gate
or move the programming point upwards.
s
Stop
The "STOP" key enables the user to stop the manoeuvre. If pressed
Set
down for more than 5 seconds it enables the user to enter programming.
Close
The "CLOSE" key enables the user to control the closing of the gate or
move the programming point downwards.
t

7.2) Programming

A number of programmable functions are available on the RUN con-
trol unit. The functions are adjusted using 3 keys set on the control
unit: [s] [Set] [t] and are used by means of 8 LEDs: L1....L8.
The programmable functions available on RUN are set out on 2
levels:

7.2.1) Level one functions (ON-OFF functions)

Table 7: programmable function list: level one:
Led
Function
L1
Automatic Closing
L2
Close After Photo
L3
Always Close
L4
Deceleration
L5
Peak
L6
Pre-flashing
L7
"Close" becomes
"Partial Open"
L8
"Slave" mode
During the normal functioning of the RUN, LEDs L1...L8 will either be on or off depending on the state of the function they represent. For
example, L1 will be on if the "Automatic Closing" function is active.
Description
This function causes the door to close automatically after the programmed time has lapsed.
The factory set Pause Time is 30 seconds, but can be changed to 5, 15, 30, 45, 60, 80, 120 or 180
seconds.
If the function is inactive, functioning will be "semi-automatic".
This function enables the gate to be kept open for the necessary transit time only. In fact the "Photo"
always causes an automatic closure with a pause time of 5s (regardless of the programmed value).
The action changes depending on whether the "Automatic closing" function is active or not.
When "Automatic Closing" is inactive: The gate always arrives to the totally open position (even if
the Photo disengages first). Automatic closing with a pause of 5s occurs when the Photo is disengaged.
When "Automatic Closing" is active: The opening manoeuvre stops immediately after the photocells
have disengaged. After 5 seconds, the gate will begin to close automatically. The "Close after photo"
function is always disabled in manoeuvres interrupted by a Stop command.
If the "Close after photo" function is inactive the pause time is that which has been programmed or there
is no automatic closing if the function is inactive.
The "Always Close" function is activated, causing closure when an open gate is detected on return of power.
A light will flash for 5 seconds before the manoeuvre starts, for safety purposes.
If the function is inactive when the power supply returns, the gate will remain stationary.
On activation of this function, a deceleration phase is activated at the end of the opening or closing
manoeuvre.
Deceleration speed corresponds to approx. 60% of the nominal speed.
Caution: during deceleration the motor develops only half of the nominal torque; the deceleration phase
is not possible on heavyweight gates or those requiring maximum torque.
If deceleration is not active the speed remains constant throughout the manoeuvre.
On activation of this function, gradual acceleration at the start of each manoeuvre is disabled; this
enables the maximum peak force and is useful in situations with high levels of static friction, such as in
the event of snow or ice blocking the leaf.
If Peak is not active the manoeuvre starts with a gradual acceleration phase.
With the pre-flashing function, a 3 second pause is added between the flashing light switching on and the
beginning of the manoeuvre in order to warn the user in advance of a potentially dangerous situation.
If pre-flashing is inactive, the flashing light will switch on when the manoeuvre starts.
By activating this function all "close" commands ("CLOSE" input or radio command "close") activate a
partial opening manoeuvre (see LED L6 on table 9).
By activating this function RUN becomes "Slave": in this way it is possible to synchronise the functioning
of two motors on opposite leaves where one motor functions as Master and the other as Slave; for further
information see paragraph "7.3.5 RUN in "Slave" mode".
23
Level one: the functions can be adjusted in modes ON-OFF (active
or inactive). In this case, each of the LEDs L1....L8 indicates a
function. If the LED is on, the function is active, if off the function is
inactive. See Table 7.
Level two: the parameters can be adjusted on a scale of values
(from 1 to 8). In this case, each of the LEDs L1...L8 indicates the
value set (there are 8 possible settings). Please refer to Table 9.