  • Page 1 0682 RUN1200HS RUN1500 Sliding Gate Opener Instructions and warnings for installation and use...
  • Page 2 400mm 253mm Max. 40mm 0÷50 0÷50...
  • Page 3 3÷8 mm...
  • Page 4 LUCYB MOFB MOSE S.C.A OPEN CLOSE 24V 4W NC NO NO NC L1 L2 L3 L4 L5 L6 L7 L8...
  • Page 5 NC NO NO NC LUCYB LUCYB MOFB MOSE STOP S.C.A OPEN CLOSE S.C.A 24V 4W 24V 4W L1 L2 L3 L4 L5 L6 L7 L8 L1 L2 L3 L4 L5 L6 L7 L8 BLUEBUS BLUEBUS...
  • Page 7: Table Of Contents

    3 .4 - Installation of the gearmotor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 manual and in combination with the articles present in the Nice S .p .a . prod- 3 .5 - Installing brackets with inductive proximity switches .
  • Page 8: Images

    before resetting it . • The automation mechanism cannot be used before it has been commis- INSTALLATION sioned as specified in the chapter on “Testing and commissioning”. • Inspect the automation mechanism frequently to check for unbalancing, signs of wear or damage to electrical cables and mechanical parts . Do not use the automation mechanism if adjustment or repair is required . 3.1 - Tests prior to installation •...
  • Page 9: Product Durability

    3.3 - Works in preparation for installation sent any form of guarantee on the effective life span of the product . fig. 2 provides an example of an automation system, produced using Nice components: Sample durability calculation: automation of a gate with a door 10 m long with a...
  • Page 10: Installation Of The Gearmotor

    TABLE 5 - Technical specifications of electric cables (fig. 2) Connection Cable type Maximum admissible length A: POWER cable 30 m (note 1) 1 cable 3 x 1 .5 mm B: Cable for FLASHER with antenna 1 cable 2 x 0 .5 mm 20 m 1 RG58 type shielded cable 20 m (recommended less than 5 m) C: PHOTOCELL cable 1 cable 2 x 0 .5 mm 30 m (note 2)
  • Page 11: Chapter 5 - Final Checks And Start-Up

    • CLOSE = input for devices which control only the closing movement . It is Device recognition, mode 2 possible to connect contacts of the “Normally Open” type to this input . This configures: • The BlueBus output with 12V auxiliary output; it may be used as a power •...
  • Page 12: Connecting Other Devices

    5.6 - Connecting other devices 06. Prepare the maintenance schedule of the automation system and deliver it to the owner; it must provide all instructions regarding the maintenance of If the user needs to feed external devices the single automation devices . such as a proximity reader for transponder 07.
  • Page 13: Chapter 7 - Programming

    PROGRAMMING 7.1 - Preset functions L1 L2 L3 L4 L5 L6 L7 L8 The RUN control unit has a number of programmable functions . These func- tions are set to a configuration which should satisfy most automations . 1.6A T 7.2 - Programming keys Flash The RUN control unit features three keys that can be used to command the...
  • Page 14: Level 2 Programming (Adjustable Parameters)

    7.5 - Level 2 programming (adjustable parameters) The adjustable parameters are factory set as shown in the Table 8 with: “ ” but can be modified at any time as shown in Table 9 . Take care during modification procedures, as there is a maximum time interval of 10 seconds between pressing one key and another; otherwise the system exits the procedure automatically memorising the changes made up to that time .
  • Page 15: Chapter 8 - Further Details

    List of mal- Result of 1 manoeuvre (most recent) The type of defect that has occurred in the functions last 8 manoeuvres can be established (see Result of 2 manoeuvre paragraph 7 .6 .1 Malfunctions log) . Result of 3 manoeuvre Result of 4 manoeuvre...
  • Page 16: Ft210B Photo-Sensor

    • Run device recognition on the Slave RUN (see paragraph 8.1.6 Recognition FOTO 3 Single photocell for the entire of the devices) . automation system • Run device recognition on the Master RUN (see paragraph 8.1.6 Recognition of the devices) . • Run gate length recognition on the Master RUN (see paragraph 5.4 Recogni- tion length of the gate) . – IMPORTANT in the case of the installation of FOTO 3 and FOTO II When connecting 2 RUNs in Master-Slave mode, make sure that: together the position of the photocell elements (TX-RX) must comply with •...
  • Page 17: Connecting And Installing The Backup Battery

    memorized in the receiver. Wait approx . 3s after which the led associated with the current level of For more information refer to the instruction manual and the “Opera system the parameter “Maintenance notification” will light up. book” manual . Press and release “s” and “t”; 8.1.9 - Connecting and installing the backup battery The led corresponding to the selected level flashes a few times. The CAUTION! –...
  • Page 18: Chapter 9 - Troubleshooting

    WHAT TO DO IF… (Troubleshooting guide) 9.1 - DIAGNOSTICS Some devices are display messages to identify their status and faults . The following paragraphs describe the messages available with the different types of device . 9.2 - Troubleshooting Table 17 gives some troubleshooting procedures, for use during installation and in case of malfunctions . TABLE 17 Troubleshooting The radio transmitter does not control the gate and the...
  • Page 19: Control Unit Signals

    3 flashes Activation of the “motor force” limiting device During the movement, the gate experienced excessive friction; identify 1 second pause the cause . 3 flashes 4 flash Activation of the STOP input At the starting of the manoeuvre or during the movement, the STOP input 1 second pause was activated;...
  • Page 20 TABLE 21 Programming leds on control unit Led 1 Description During normal operation the device indicates “Automatic Closing” is not active . During normal operation the device indicates “Automatic Closing” is active . It flashes • Function programming in progress. • If it flashes together with L2, it means that the user must carry out the device recognition phase (see par. 4.3). Led 2 Description During normal operation the device indicates “Close after photo” is not active . During normal operation the device indicates “Close after photo”...
  • Page 21: Technical Characteristics

    TECHNICAL SPECIFICATIONS OF PRODUCT WARNINGS: • All technical specifications stated in this section refer to an ambient temperature of 20°C (± 5°C). • Nice S.p.a. reserves the right to apply modifications to products at any time when deemed necessary, maintaining the same intended use and functionality. Model: RUN1200HS RUN1500 Type Electromechanical gearmotor for automatic movement of sliding gates for industrial use complete with elec- tronic control unit . Pinion Maximum torque on start-up [cor- 35Nm 27 .4Nm responds to ability of generating the (790N) (1000N) force required to move the leaf] Nominal torque [corresponds to the 20Nm 10 .3Nm...
  • Page 22 USER MANUAL (end user version) Before using the automation for the first time, ensure that the installer explains the sources of residual risks, and take care to read the instruc- tion manual. Keep the manual for consultation when in doubt and ensure supply to new owners of the automation. CAUTION! - Your automation is a machine that performs commands imparted by the user; negligent or improper use may con- stitute a hazard: - Never activate automation controls if persons, animals or objects are present in the operating range. - NEVER touch parts of the automation while the gate is moving! - Photocells do not constitute actual safety devices, but are rather safety aids.
  • Page 23 CE MARK DECLARATION OF CONFORMITY and declaration of incorporation of partly completed machinery Declaration in accordance with the following Directives: 2004/108/EC (EMC); 2006/42/EC (MD) annex II, part B Declaration number: 500/RUN..HS Revision: 1 Language: EN Manufacturer's NICE s.p.a. Name: Address: Via Pezza Alta 13, Z.I. Rustignè, 31046 Oderzo (TV) Italy Person authorized to compile the technical documentation: NICE s.p.a. Type of product: Electromechanical gearmotor with incorporated control unit Model / Type: RUN1200HS, RUN400HS Accessories: PS524 battery charger, radio receiver mod. SMXI, SMXIS or ONEXI The undersigned Mauro Sordini, as Chief Executive Officer, hereby declares under his own responsibility that the product identified above complies with the provisions of the following directives: • DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 15 December 2004 on the approximation of the laws of the Mem- ber States relating to electromagnetic compatibility and repealing Directive 89/336/EEC, in accordance with following harmonised standards: EN 61000-6-2:2005, EN 61000-6-3:2007+A1:2011 In addition, the product conforms to the following directive in accordance with the provisions applicable to partly completed machinery: • Directive 2006/42/EC OF THE EUROPEAN PARLIAMENT AND COUNCIL of May 17 2006 regarding machines and amending directive 95/16/EC (consoli- dated text) • I hereby declare that the pertinent technical documentation has been drafted in accordance with Annex VII B of Directive 2006/42/EC and that the following essential require- ments have been fulfilled: 1.1- 1.1.2- 1.1.3- 1.2.1-1.2.6- 1.5.1-1.5.2- 1.5.5- 1.5.6- 1.5.7- 1.5.8- 1.5.10- 1.5.11...
  • Page 24 Nice SpA Oderzo TV Italia www.niceforyou.com info@niceforyou.com...