Cardinal 758 Operation Manual page 12

Weight indicating instrument
Table of Contents

Advertisement

1. Press ON | OFF key to turn off.
2. Remove calibration jumper J1.
3. Press ON | OFF key to turn on.
i n t =
dp=
0 = XXXXX
1 = XXXX.X
CAP=
Unt=
1 = lb only
2 = kg only
4 = kg / lb
5 = oz only
l o a d =
Press PRINT twice to bypass
or once and enter test weight
value and load scale.
Press PRINT again.
u n l o a d
t r a =
t r l =
f l t =
0 = No Filtering
1 = Minimal
SETUP and CALIBRATION, Cont.
Interval
1,2 or 5
Decimal Point
Location
0,1,2 or 3
2 = XXX.XX
3 = XX.XXX
Scale
Capacity
up to 99,999
W e i g h i n g
Units
3 = lb / kg
6 = grams only
Calibration
Weight
Remove
Test Weights
Zero Tracking
Range
1,2,3,4,5,6,7,
8,9 or 10=(.5)
0 to disable
4% Zero
Tracking Limit
1=Yes 0=No
Filtering?
0,1, 2 or 3
2 = Moderate
3 = Custom
If Filtering=0, 1 or 2 then
If Filtering=3 then
F =
b r =
Uns=
s r =
puo=
asH=
sLp=
bAUd
P C =
C r l f
eop=
done
11
Filter Level
1 to 16
Break Range
1 to 64
Motion Range
1 through 9
Sample Rate
1 to 8
Power Up
Zero
Auto Shutoff
0=Disable
1 to 9 Minutes
Sleep Mode
0=Disable
1 to 9 Minutes
BAUD Rate
1=1200 2=2400
3=4800 4=9600
5=19,200
Printer
Continuous
Output
Carriage
Return
Line Feed
End-of-Print
Line Feeds
CALIBRATION COMPLETE