Specify Power Supply Autodetection

KX III provides dual power supplies.
When both power supplies are used, KX III automatically detects
them and notifies you of their status. Additionally, both the
Powerln1 and Powerln2 Auto Detect checkboxes are automatically
selected on the Power Supply Setup page.
If you are using only one power supply, you can enable automatic
detection for only the power supply in use.
When only one power input is connected, the Power LED on the
front of the KX III device is Red when the checkbox is selected for
an unconnected power supply, and Blue when the checkbox is not
selected for an unconnected power supply.
 To enable automatic detection for the power supply in use:
1. Select Device Settings > Power Supply Setup.
Select the Powerln1 Auto Detect option if you are plugging
power input into power supply number one.
(The left-most power supply at the back of the device
when you are facing rear of the device.)
Or
Select the Powerln2 Auto Detect option if you are plugging
power input into power supply number two.
Dominion KX III Quick Setup Guide
QSG-DKX3-v3.6.9-0L-E  255-62-0003-00-RoHS
(The right-most power supply at the back of the device
when you are facing rear of the device.)
2. Click OK.
Configure Date/Time Settings
The date and time settings impact SSL certificate validation if LDAPS
is enabled. Configuring the date and time also ensures your audit
logs will be timestamped correctly.
There are two ways to do this:
Manually set the date and time.
6