olympia electronics GR-292/M/HL Manual

olympia electronics GR-292/M/HL Manual

Self testing non-maintained emergency ceiling mounted luminaires

Advertisement

Quick Links

SELF TESTING NON-MAINTAINED EMERGENCY CEILING MOUNTED LUMINAIRES
TECHNICAL CHARACTERISTICS
OPERATION VOLTAGE
MAXIMUM POWER CONSUMPTION
BATTERY (Ni-MH)
BATTERY PROTECTION
INDICATIONS - CONTROLS
CHARGE TIME
MINIMUM DURATION
LIGHT SOURCE
EMERGENCY ILLUMINATION
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH
OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY
CONSTRUCTION MATERIAL
EXTERNAL DIMENSION
WEIGHT
GUARANTEE
GENERAL
This device is used indoors (ta 40 C) in places
where emergency luminaires are needed.
Each device must be permanently connected
to mains power supply. The GR-292/M/HL is
suitable for corridors lighting and the GR-
293/M/HL for open area lighting. In normal
operation the battery is charging. In case of a
mains power supply failure, the device enters
emergency mode and the illumination LED
turns on. When the mains power supply is
restored, the device turns to normal operation.
INSTALLATION
To install the luminaire follow the installation
instructions οn page 3.
Battery Charging
The battery charging is completely controlled.
In this case, is achieved the perfect battery
maintenance , as well as the elongation of its
duration. When the battery has completely
charged, it charges with a maintenance
current.
Battery Cut-off
The device enters this mode when the mains
power supply has failed and battery has lost its
energy. During this mode the device enters in
idle
state
and
Page 1 from 6
EN 60598-1, EN 60598-2-22, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3
Thank you for your trust in our products
Olympia Electronics - European manufacturer
o
battery
consumption
(for LED MODULE specifications see page 5)
GR-292/M/HL
220-240V AC / 50-60Hz
4.9W / 5.2 VA
4.8V/4Ah
Deep discharge and overcharge protection
Charge, lamp fault, battery fault, TEST button
24 hours
3 hours
1 white power LED
330lm
5 to 40 C
Up to 95%
ABS/PC
Ø125 x 72 mm
737gr.
3 years (1 year for the battery)
negligible, in order to be protected from deep
discharge.
Manual Test
This test can be done by pushing the test
button. The light source and the emergency
circuit of the device are monitored. The manual
test can be conducted only if the main power
supply and the battery are connected. During
this test period all indication LEDs are OFF.
Automatic Operational Test
This test includes all the operations that provide
the manual test and is conducted automatically
every 15 days. In order to be performed, the
mains power supply and the battery should be
connected.
Automatic Autonomous Test
This test monitors the device's back up
operation
and
BATTERY FAULT LED blinks during the test,
indicating this process to the user. This test is
conducted automatically every six months. In
order to be performed, the mains power supply
should be connected and the battery must be
fully charged. If the battery is not fully charged,
the test is postponed until the battery is
completely charged. If during this test, the
is
autonomy is less than the nominal then the
GR-293/M/HL
IP20
o
emergency
duration.
923293007_09_001
The

Advertisement

loading

Summary of Contents for olympia electronics GR-292/M/HL

  • Page 1 Each device must be permanently connected Manual Test to mains power supply. The GR-292/M/HL is This test can be done by pushing the test suitable for corridors lighting and the GR- button. The light source and the emergency 293/M/HL for open area lighting.
  • Page 2: Labeling Explanation

    battery fault led turns on continuously indicating Connection to module (After request) that the battery must be replaced. This luminaire can be connected to any of the following modules: Remote module, address Back Up Operation module, wireless module and fault relay The autonomous duration of battery during module.
  • Page 3: Installation Instructions

    INSTALLATION INSTRUCTIONS Cable entry hole Initial installation 1 Untighten the screw and pull up the reflector. 2 Always use in any case round mains cable, with a diameter of 5-10mm (H05RN-F type 2x1mm² or any other type, at least equal to it’s mechanical and electrical properties). Make a hole in the center of the gasket by using a small screwdriver.
  • Page 4 Mounting the lamp in suspended ceiling. Set up the lamp to the suspended ceiling as it is shown bellow (Required opening 110mm): Step 1 Pass the battery pack into the ceiling then bend the springs, to get into the hole of the suspended ceiling, as you can see to the next figure.
  • Page 5 Test Figure 4 button A-290/BAT 286 mm 31 mm 33 mm LED MODULE CHARACTERISTICS GR-292/M/HL GR-293/M/HL Olympia Electronics S.A. Manufacturer Model Number 0405185 Voltage Range 3-3,2V DC Nominal Power 2.3W fixed connection between main pcb and led module Connections Temperature (tc) 75 C max.
  • Page 6: Warranty

    Olympia Electronics reserves the right to repair or to replace the returned goods and to or not charge the buyer depending on the reason of defection. Olympia Electronics reserves the right to charge or not the buyer the transportation cost.

This manual is also suitable for:

Gr-293/m/hl