Download Print this page

olympia electronics GRL-29 WP Manual

Waterproof addressable self-testing non-maintained emergency luminaire

Advertisement

Quick Links

WATERPROOF ADDRESSABLE SELF-TESTING NON-MAINTAINED EMERGENCY LUMINAIRE
TECHNICAL CHARACTERISTICS
OPERATION VOLTAGE
MAXIMUM POWER CONSUMPTION
BATTERY (Pb)
BATTERY PROTECTION
INDICATIONS - CONTROLS
CHARGING TIME
MINIMUM AUTONOMOUS DURATION
LIGHT SOURCE
EMERGENCY ILLUMINATION
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH
OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY
CONSTRUCTION MATERIALS
EXTERNAL DIMENSIONS
TYPICAL WEIGHT
GUARANTEE
GENERAL
These luminaires are used indoors (ta 40 C)
where emergency light is needed. Each
luminaire must be connected permanently to
the mains power supply.
OPERATION DESCRIPTION
When the unit is connected to the mains power
supply (after connecting the battery) the
indicator LAMP FAULT – BATT. FAULT remains
OFF whereas the indicator POWER CHARGE
blinks to indicate that the batteries are charging.
When the batteries are fully charged this
indicator will light permanently. If this indicator
does not light then probably the battery has not
been connected. If the batteries are connected
and the indicator does not light then contact a
qualified service technician for assistance. The
charging procedure is monitored by a
microprocessor and is based on a 3 stage cycle
thus ensuring a fast and full charge of the
battery. The charge current is supplied by a high
efficiency switch mode power supply which
ensures perfect charging even during the
fluctuations of the mains power supply.
BATTERY CUTOFF
The unit enters this state during the power
supply failure and when the battery has been
Page 1 from 7
POWER-CHARGE indicator, LAMP FAULT–BATT. FAULT indicator, TEST button
EN 60598-1, EN 60598-2-22, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3
Thank you for your trust in our products
Olympia Electronics - European manufacturer
(for LED MODULE Specifications see page 3)
GRL-29/WP/ADR
220-240V AC/50-60Hz
12.6W/13.1VA
12V/7Ah
From overcharge and deep discharge
24h
180 min
White LEDs
1760lm
IP65
5 to 40 C
Up to 95%
ABS/PC, PC
302 x 94 x 345 mm
3687gr.
3 years (1 year for the battery)
fully discharged. In this state the luminaire
o
draws the least power from the battery in order
to prevent deep discharge.
MANUAL TESTING
Is accomplished by briefly (<1 sec.) pressing the
TEST button. This permits the user to test the
good operation of the luminaire's emergency
circuit. The unit simulates a power failure and
the lamps are lit using the batteries. This manual
test does not affect the automatic test.
DIMMING OPTION
When the luminaire is in emergency mode, with
corresponding pressings of the button, we can
choose the illumination of 100%, 50%, 33% or
turned off, either to increase the autonomy time
or not to consume the battery power
unnecessarily. This option is canceled when the
network is restored.
ADDRESSABLE COMMUNICATION
The luminaire has the ability to be connected
to GR-6500 panel. In order to do so, the
luminaire's address has to be unique in the
same bus. For more details see page 3
(installation instruction).
o
923029012_09_001

Advertisement

loading

Summary of Contents for olympia electronics GRL-29 WP

  • Page 1 TYPICAL WEIGHT GUARANTEE 3 years (1 year for the battery) Thank you for your trust in our products Olympia Electronics - European manufacturer GENERAL fully discharged. In this state the luminaire These luminaires are used indoors (ta 40 C) draws the least power from the battery in order where emergency light is needed.
  • Page 2 LAMP TESTING WARNING !!! The luminaire tests the good condition of the 1. Every test, installation or maintenance lamps in emergency mode and warns the user procedure must be done only by qualified for probable malfunction. If a lamp is found faulty personnel.
  • Page 3: Labeling Explanation

    The light source contained in this luminaire shall only be replaced by the manufacturer, or his agent, or a similar qualified person. NOTE! The light source is non-user replaceable. LED MODULE CHARACTERISTICS GRL-29/WP/ADR Olympia Electronics S.A. Manufacturer Model Number 2002163 Voltage Range...
  • Page 4 INSTALLATION PROCEDURE (wall installation only) Mounting holes Cover retaining screws LAMP FAULT POWER BATT. FAULT CHARGE indicator indicator TEST GR-6500 Loop button 2 3 4 5 6 7 8 Dipswitch Position 1. Use the supplied mounting accessories to mount the device. 2.
  • Page 5 Dipswitch Dipswitch Dipswitch Dipswitch Address Address Address Address setting setting setting setting Page 5 from 7 923029012_09_001...
  • Page 6 Dipswitch Dipswitch Dipswitch Dipswitch Address Address Address Address setting setting setting setting Page 6 from 7 923029012_09_001...
  • Page 7: Warranty

    Olympia Electronics reserves the right to repair or to replace the returned goods and to or not charge the buyer depending on the reason of defection. Olympia Electronics reserves the right to charge or not the buyer the transportation cost.

This manual is also suitable for: