Download Print this page
olympia electronics GR-2110 Quick Start Manual

olympia electronics GR-2110 Quick Start Manual

Slim classic light series for non maintained / maintained (optional) emergency luminaires

Advertisement

Quick Links

'' SLIM CLASSIC LIGHT '' SERIES FOR NON MAINTAINED / MAINTAINED
GR-2110
TECHNICAL CHARACTERISTICS
OPERATION VOLTAGE
MAXIMUM POWER CONSUMPTION
BATTERIES (Ni-Cd)
INDICATIONS - CONTROLS
CHARGING TIME
MINIMUM AUTONOMOUS DURATION
ILLUMINATION SOURCE
ILLUMINATION (230V AC / emergency)
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH
OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY
CONSTRUCTION MATERIALS
EXTERNAL DIMENSIONS
TYPICAL WEIGHT
GUARANTEE
GENERAL
These luminaires are used indoors (ta 40 C)
where emergency light is needed.
Each luminaire must be permanently
connected to mains power supply. In normal
operation the illumination LEDs are lit as well
as the green indicating charge LEDs when
the battery is charging.
In case of a mains power supply failure the
luminaire will light the led strip automatically
in emergency mode. When the mains power
supply is restored the device turns to normal
operation.
Non Maintained / maintained operation
t h e r e i s a n o p t i o n t o s e l e c t t h e n o n
maintained or maintained operation by
placing the jumper to the appropriate place
according to the figure 3 (page 2).
INSTALLATION
To install the luminaire follow the installation
instructions on page 2.
ΑΤΤΕΝΤΙΟΝ!!!
1. Operations for installation, maintainance or
testing must be done by authorized personel
only.
2. The device must be connected to the
m a i n s p o w e r s u p p l y t h r o u g h a f u s e
dependent by the total amount of the line's
power load.
Page 1 from 3
(OPTIONAL) EMERGENCY LUMINAIRES
EN 60598-1, EN 60598-2-22, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3
Thank you for your trust in our products.
Olympia Electronics - European manufacturer.
o
(for LED MODULE Specifications see page 3)
220-240V AC/50-60Hz
3W / 3.5VA
3.6V/1Ah
Battery charge indication LEDs, TEST button
24 h
3 h
12 White LEDs
40lm / 100lm
IP 30
5 to 40 C
up to 95%
Bayblend FR3010, transparent polycarbonate
292 x 111 x 54 mm
495gr.
3 years (1 year for the battery)
3. It is suggested to check every month the
indication LED for battery charging, and by
pushing the TEST button to check the
emergency circuit. The led strip should light as
long as the TEST button is pressed.
luminaire doesn't work as described above
contact the installer.
4. It is suggested to check every 6 months the
m i n i m u m a u t o n o n o u s d u r a t i o n b y
disconnecting the mains power supply. Count
the time that the led strip lights and in case of
less time than the minimum autonomous
duration the battery must be replaced. If the
measured time is considerably less than the
minimum autonomous duration
installer.
In case of battery or led strip
replacement, these must be replaced by parts
of the same type, by the manufacturer or by a
competent person.
5. In case of inactive use for a period greater
than 2 months, disconnect the battery by
pulling out the battery's connector.
6. I s not allowed to discard batteries in to
t i
c o m m o n t r a s h b i n s , t h e y m u s t b e
discarded only
points. Do not incinerate.
o
contact the
in battery recycling
923211002_09_004
If the

Advertisement

loading

Summary of Contents for olympia electronics GR-2110

  • Page 1 495gr. 3 years (1 year for the battery) GUARANTEE Thank you for your trust in our products. Olympia Electronics - European manufacturer. GENERAL 3. It is suggested to check every month the These luminaires are used indoors (ta 40 C) indication LED for battery charging, and by where emergency light is needed.
  • Page 2 Installation instructions Figure 1 Figure 2 Figure 3 Maintained Non-maintained operation oparation Connection terminal block on the PCB For fuce ratings see text Figure 4 1. To instal the device you have to dismantle carefully the device with a flat screwdriver as shown in figure 1.
  • Page 3 Installation instructions Figure 1 Figure 2 Figure 3 Maintained Non-maintained operation oparation Connection terminal block on the PCB For fuce ratings see text Figure 4 1. To instal the device you have to dismantle carefully the device with a flat screwdriver as shown in figure 1.