TECHNICAL CHARACTERISTICS
OPERATION VOLTAGE
MAXIMUM POWER CONSUMPTION
BATTERY (Ni-MH)
BATTERY PROTECTION
INDICATIONS - CONTROLS
CHARGE TIME
MINIMUM DURATION
LIGHT SOURCE
EMERGENCY ILLUMINATION
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH
OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY
CONSTRUCTION MATERIAL
EXTERNAL DIMENSION
WEIGHT
GUARANTEE
GENERAL
These devices are used indoors (ta 40 C)
in places where emergency luminaires are
needed. The luminaires GR-270 and GR-
272 are suitable for corridors lighting and
the GR-271 and GR-273 for open area
lighting. Each device must be permanently
connected to mains power supply. In
normal operation the battery is charging. In
case of a mains power supply failure the
device will light the illumination led
automatically in emergency mode. When
the mains power supply is restored the
device turns to normal operation.
INSTALLATION
To install the luminaire follow the
installation instructions οn page 2.
ΑΤΤΕΝΤΙΟΝ!!!
1. Operations for installation, maintainance
or testing must be done by authorized
personel only.
2. The device must be connected to the
mains power supply thru a fuse dependent
by the total amount of the line's power
load.
3. It is sugested to check every month the
indication LED for battery charging, and by
pushing the TEST button (use a pointy tool
Page 1 from 4
NON MAINTAINED SPOT LIGHT EMERGENCY
LUMINAIRES WITH 1 WHITE POWER LED
GR-270
EN 60598-1, EN 60598-2-22, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3
Thank you for your trust in our products
Olympia Electronics - European manufacturer
(for LED MODULE specifications see page 4)
GR-271
220-240V AC / 50-60Hz
2.4W / 2.7VA
3.6V/1.5Ah
Deep discharge and overcharge protection
Charge, TEST button
1.5 hour
1 white power LED
160lm
Up to 95%
ABS/PC, PC
Ø125 x 65 mm
3 years (1 year for the battery)
with diameter of 2mm max.) to check the
o
emergency cirquit. The illumination LED
should light as long as the TEST button is
pressed. In the opposite condition contact
the installer.
4. It is sugested to check every 6 months
the minimum autononous duration by
disconnecting the mains power supply.
Count the time that the luminaire lights and
in case of less time than the minimum
autonomous duration the battery must be
r e p l a c e d . I f t h e m e a s u r e d t i m e i s
considerably less than the minimum
autonomous duration
I n c a s e o f b a t t e r y o r l i g h t s o u r c e
replacement, these must be replaced by
parts of the same type, by the manufacturer
or by a competent person.
5. In case of inactive use for a period
greater than 2 months, disconnect the
b a t t e r y b y p u l l i n g o u t t h e b a t t e r y 's
connector.
6. I s not allowed to discard batteries in
t i
to common trash bins, they must be
discarded only
points. Do not incinerate.
GR-272
24 hours
3 hours
120lm
IP40
o
5 to 40 C
380gr.
contact the installer.
in battery recycling
923270000_09_004
GR-273