SELF TESTING NON-MAINTAINED EMERGENCY CEILING MOUNTED LUMINAIRES WITH WIRELESS COMMUNICATION
TECHNICAL CHARACTERISTICS
OPERATION VOLTAGE
MAX. SUPPLY CURRENT
MAXIMUM POWER CONSUMPTION
MINIMUM POWER FACTOR (λ)
U-OUT
BATTERY
INSULATION BETWEEN SUPPLY & CONTROL TERMINALS
INSULATION BETWEEN SUPPLY & BATTERY CIRCUIT
WORKING VOLTAGE AT WHICH THE INSULATION IS DESIGNED
BATTERY PROTECTION
BATTERY VOLTAGE RANGE
BATTERY SUPPLY CURRENT DURING EMERGENCY
BATTERY CHARGE CURRENT RANGE
BATTERY DISCHARGE CURRENT RANGE
TX/RX FREQUENCY RANGE
TX POWER
INDICATIONS - CONTROLS
CHARGE TIME
MINIMUM DURATION
LIGHT SOURCE
EMERGENCY ILLUMINATION
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH
OPERATION TEMPERATURE RANGE
Prated/Irated
CONTROL GEAR MAX.TEMPERATURE (tc)
RELATIVE HUMIDITY
CONSTRUCTION MATERIAL
EXTERNAL DIMENSION
WEIGHT
GUARANTEE
CONTROL GEAR WITH AUTOMATIC
TEST FUNCTION
GENERAL
This device is used indoors (ta 40 C) in places
where emergency luminaires are needed. Each
device must be permanently connected to mains
power supply. The luminaires GR-290/M/WL
and GR-292/M/WL are suitable for corridors
lighting and the GR-291/M/WL and GR-
293/M/WL for open area lighting. In normal
operation the battery is charging. In case of a
mains power supply failure, the device enters
emergency mode and the illumination LED turns
on. When the mains power supply is restored
the device turns to normal operation.
Page 1 from 6
GR-290/M/WL
EN 60598-1, EN 60598-2-22, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3
Controlgear is suitable for LED module only
The controlgear has mains-connected windings of transformer
Thank you for your trust in our products
Olympia Electronics - European manufacturer
o
(for LED MODULE specifications see page 6)
GR-291/M/WL
220-240V AC / 50-60Hz
19.5mA AC
4.3W / 4.7 VA
4.8V/1.2Ah, NiMH (4KRMT 15/51)
Basic insulation
Basic insulation
Deep discharge and overcharge protection
(Vbat=4.8V):500mA
130 - 200mA (normal charge) / 20 - 30mA (trickle charge)
400 - 600mA
868.150-868.450MHz
Charge, lamp fault, battery fault
24 hours
1.5 hour
1 white power LED
300lm
5 to 40 C
2.1W/660mA
65°C at Q2
Up to 95%
Ø125 x 65 mm
3 years (1 year for the battery)
Manual Operational Test
This test can be done by pushing the test button.
The light source and the emergency circuit of the
device are tested. The manual test can be
conducted only if the mains power supply and the
battery are connected. During this test period the
LAMP TEST LED will blink. The battery must
have adequate charge. This test lasts for 3
seconds.
GR-292/M/WL
0.9
6V
500V
4-6V
(Vbat=4.8V):230mA
180 - 300mA
11dBm
3 hours
150lm
IP40
o
1W/320mA
ABS/PC
442gr.
923293010_09_002
GR-293/M/WL