  • Page 1 Keysight M9485A PXIe Vector Network Analyzer Modules M9310A, Source Output M9300A, Frequency Reference M9309A, Synthesizer M9340A, Distributor M9376A, VNA Receiver Startup Guide...
  • Page 2 FOR A PARTICULAR PURPOSE. procedure, practice, or the like that, if KEYSIGHT SHALL NOT BE LIABLE FOR not correctly performed or adhered to, ERRORS OR FOR INCIDENTAL OR could result in damage to the product CONSEQUENTIAL DAMAGES IN or loss of important data.
  • Page 3: Table Of Contents

    STEP 5. Verify Operation of the Network Analyzer Modules The Operator’s Check 2 ....Getting Help with Your Network Analyzer Module Help System Contacting Keysight...
  • Page 4 Contents...
  • Page 5: Getting Started

    You may add as many receivers as you require and have n-port Network Analyzers up to 24-ports, according to the number of receiver modules. Each module can be controlled with the M9485A Soft Front Panel and SCPI commands. This allows you to make the network analyzer measurement just as the n-port Network Analyzer.
  • Page 6: Step 1. Unpack And Inspect The Network Analyzer Modules

    Getting Started STEP 1. Unpack and Inspect the Network Analyzer Modules STEP 1. Unpack and Inspect the Network Analyzer Modules The network analyzer modules are shipped in materials which prevent damage from static. CAUTION The modules should only be removed from the packaging in an anti-static area ensuring that correct anti-static precautions are taken.
  • Page 7: Inspect For Damage

    Should it become necessary to return a network analyzer module for repair or service, follow the steps below: 1. Review the warranty information shipped with your product. 2. Contact Keysight to obtain a Return Material Authorization (RMA) and return address. For assistance finding Keysight contact information, go to www.keysight.com/find/assist (worldwide contact information for repair and service).
  • Page 8: Step 2. Check The Shipment

    Getting Started STEP 2. Check the Shipment STEP 2. Check the Shipment The M9485A consists of several modules, cables and dividers. Use the Contents List in the shipping container to verify the completeness of your shipment. If not complete, refer to...
  • Page 9: Step 3. Install The Network Analyzer Modules

    Ensure proper chassis air flow is maintained. • The use of a Keysight M9018A chassis is recommended for optimum temperature control. If a different chassis is used, make sure it provides thermal protection if fans become inoperable or forced air cooling is obstructed.
  • Page 10: Installation Procedure

    Getting Started STEP 3. Install the Network Analyzer Modules • Socket adapter (part number M9485-23001) - supplied. • Torque driver (for use with socket adapter), set to 8 in-lb (0.91 N.m) - not supplied. • Cable removal tool (part number 5002-3361) - supplied. •...
  • Page 11 Getting Started STEP 3. Install the Network Analyzer Modules b. Hold down the silver locking tab while pushing down the injector/ejector handle to the unlatched (downward) position, and slide the module to the rear of the chassis. c. Slide the module completely into the chassis. When you begin to feel resistance, pull up on the injector/ejector handle to fully inject the module into the chassis.
  • Page 12 Getting Started STEP 3. Install the Network Analyzer Modules 11.If the number of receiver is equal or less than 6, up to 6-port module on a single chassis configuration (Figure 1-5 on page 12) can be applied. Receivers should be installed from right to left and not otherwise. Figure 1-4 Up to 12-port Module in One Chassis Configuration Figure 1-5...
  • Page 13 Getting Started STEP 3. Install the Network Analyzer Modules Figure 1-6 Up to 24-port Module in Two Chassis Configuration Figure 1-7 Up to 12-port Module in Two Chassis Configuration...
  • Page 14 18.2-port modules have the option of using 3 of the M9376-62004 2-way divider. If you are using other chassis than Keysight’s, you may need a routing for trigger path of NOTE the chassis. Refer to the M9485A FAQ page on the Keysight.com for more information (http://www.keysight.com/find/m9485A)
  • Page 15 Getting Started STEP 3. Install the Network Analyzer Modules Figure 1-9 Installing 4-Way Divider SMP-SMP connectors are furnished with the divider at factory shipment. NOTE...
  • Page 16 Getting Started STEP 3. Install the Network Analyzer Modules Insert the SMP-SMP connectors into the receiver’s input carefully as they are very CAUTION sensitive and the inner conductors tend to bend. 19.Place the labels on the divider as shown in Figure 1-10 on page 16 below, on the dividers.
  • Page 17 Getting Started STEP 3. Install the Network Analyzer Modules The IF Out port of the VNA receiver is terminated with 50 ohm load. This 50 ohm load can NOTE be used at the Operator’s check. Figure 1-12 Cable Connections Between Modules for 12-port Configuration Figure 1-13 Cable Connections Between Modules for 24-port Configuration...
  • Page 18 Getting Started STEP 3. Install the Network Analyzer Modules Table 1-1 Part Numbers of Required Cables for Connection Cable Part Numbers Cable Type Required Tool to Place the Cable 8120-5091 Flexible M9485-61601 Flexible 8 in-lbs Torque Wrench for SMA (not supplied) M9485-61602 Flexible M9485-61603...
  • Page 19 Getting Started STEP 3. Install the Network Analyzer Modules Cable Part Numbers Cable Type Required Tool to Place the Cable M9485-61611 Semi rigid Socket and torque driver (to be used with M9485-61612 Semi rigid socket adapter), set to 8 in-lb (not supplied) M9485-61613 Semi rigid M9485-61614...
  • Page 20: Step 3. Install The Software

    Runs one of the operating systems listed in System Requirements (above). Remote controller (For Keysight M9018A chassis use only) A PC running one of the operating systems listed in System Requirements and a Keysight M9021A Cable Interface x8 with one of the following PC interface options: •...
  • Page 21: Power Up The Controller

    If you are using a remote controller, complete the following steps: 1. Install the cable interface between the remote controller and the chassis. If you are using an Keysight M9021A cable interface, refer to the Keysight M9021A documentation for further details.
  • Page 22 Getting Started STEP 3. Install the Software Software Installation Procedure 1. Install the Keysight IO Libraries Suite, using either the Keysight IO Libraries Suite CD included with your shipment, or the downloadable file at www.keysight.com/find/iosuite. Follow the installer prompts to install the IO libraries.
  • Page 23: Step 5. Verify Operation Of The Network Analyzer Modules

    The operator’s check is not complete solution to find all malfunctions. Hence, perform the verification and performance tests to check the complete performance of M9485A. Operator’s check is executed at the Soft Front Panel boot up default. You can turn off the start up test by the preference setting (System > System Setting >...
  • Page 24 Getting Started STEP 5. Verify Operation of the Network Analyzer Modules...
  • Page 25: Getting Help With Your Network Analyzer Module

    Getting Help with Your Network Analyzer Module Help System M9485A PXIe Startup Guide Getting Help with Your Network Analyzer Module Help System Use the Help System to quickly reference programming and user documentation To access Help: • From the analyzer module software —...
  • Page 26: Contacting Keysight

    Assistance with test and measurements needs and information on finding a local Keysight office are available on the Web at: www.keysight.com/find/assist. If you do not have access to the Internet, please contact your Keysight field engineer. In any correspondence or telephone conversation, refer to the Keysight product by its NOTE model number and full serial number.
  • Page 27 This information is subject to change without notice. © Keysight Technologies 2015 *M9485-90000* www.keysight.com...