Advertisement

Quick Links

Keysight
11612A
Bias Network
Includes Option 001
Serial Numbers: This manual applies directly to
Keysight 11612A Bias Networks with serial number
prefix 2301A and higher.
Operating and
Service Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 11612A and is the answer not in the manual?

Questions and answers

Summary of Contents for Keysight 11612A

  • Page 1 Keysight 11612A Bias Network Includes Option 001 Serial Numbers: This manual applies directly to Keysight 11612A Bias Networks with serial number prefix 2301A and higher. Operating and Service Manual...
  • Page 3: Manual Part Number

    Should Keysight and the user have a separate written agreement with warranty terms covering the material WA R N I N G in this document that conflict with...
  • Page 4 11612A Bias Network NOTE In the following graphic, all dimensions are in millimeters. Figure 1 11612A Dimensions 11612A Operating and Service Manual...
  • Page 5: General Information

    General Information The 11612A bias network provides a means of supplying dc bias to the center conductor of a coaxial line of a component or device while blocking the DC bias to the RF input port. This manual contains information required to install, operate, and test the 11612A bias network.
  • Page 6 It is critical that you properly set the power levels before connecting the bias network to the power supply. Failure to do so may result in irreparable damage to the bias coil. Bias coils damaged by overheating are not covered under warranty. 11612A Operating and Service Manual...
  • Page 7: Supplemental Characteristics

    The electrical performance of the bias network is independent of its pin depth within the range stated above. b. 3.5 mm connectors mate with SMA connectors. 11612A Option 001 Supplemental Characteristics 0.000 to 0.127 mm (0.0000 to 0.0050 inches) Pin Depth...
  • Page 8: Operation

    The circuit is a “tee” in which the capacitor in the left arm acts as a DC block/high pass filter. The vertical arm, with its series inductance and shunt capacitance, acts as a low pass filter. Figure 2 Bias Network Schematic Diagram 11612A Operating and Service Manual...
  • Page 9 The following procedure sets the correct power levels for the bias network when you’re using it for pulsed measurements. This procedure applies only to the 11612A option 001 high current bias network and should not be used with the standard 11612A.
  • Page 10: Storage And Shipment

    Altitude up to 7,625 meters (25,000 feet), mean sea level Returning a Device to Keysight If your device requires service, contact Keysight Technologies for information on where to send it. See “Contacting Keysight” on page 11. Include the following information: •...
  • Page 11: Performance Tests

    1. Connect the equipment for a standard reflection measurement. 2. Calibrate the system with an open and a short. 3. Connect the appropriate RF port of the 11612A to the network analyzer test port. Terminate the opposite port with a 50 ohm load.
  • Page 12 0.4 to 1 GHz 8 to 18 GHz 1 to 18 GHz 18 to 26.5 GHz 18 to 26.5 GHz Insertion Loss 0.045 to 12.4 GHz 0.4 to 12.4 GHz 12.4 to 26.5 GHz 12.4 to 26.5 GHz 11612A Operating and Service Manual...
  • Page 13 Figure 5 11612A Option 001 Duty Cycle Curves, Overall View 11612A Operating and Service Manual...
  • Page 14: Contacting Keysight

    Figure 6 11612A Option 001 Duty Cycle Curves, Overall View Contacting Keysight Assistance with test and measurement needs and information on finding a local Keysight office are available on the Web at: www.keysight.com/find/assist NOTE In any correspondence or telephone conversation, refer to the Keysight product by its model number and full serial number.
  • Page 15 11612A Operating and Service Manual...
  • Page 16 This information is subject to change without notice. © Keysight Technologies 1989 - 2015 January 2015 *11612-90001* 11612-90001 www.keysight.com...