Download Print this page

New Transmitter; Recording A New Transmitter; Restoring Factory Mode With A New Transmitter - SOMFY Altus RTS Programming And Limit Setting Instructions

Advertisement

3)
Resetting the motor's memory and recording a new
transmitter when the only transmitter is lost.
**A.
Perform a double power cut in the following sequence:
1. Power-off - 2 sec. minimum
2. Power-on - 5 to 15 seconds
3. Power-off - 2 sec. minimum
4. Power-on
The end product moves for 5 seconds in one direction,
to indicate that the double power cut has been
recorded.The motor is in a PROGRAMMING STATE
for 2 minutes.
B

Recording a New Transmitter

.
Press the programming button of the NEW RTS transmitter
For 1 second max. Release it after the end-product jogs briefly
UP/DOWN indicating that the transmitter has erased all previous
transmitters and recorded the NEW one.
C

Restoring Factory mode with a New Transmitter

.
Press and HOLD the programming button of the NEW RTS
transmitter for more than 7 seconds. The end-product will jog
briefly UP/DOWN twice. Once after 1 second and again after 7
seconds. This indicates the ALTUS/OREA RTS motor has been
completely cleared.
4)
Back to the factory configuration (to completely reset the ALTUS RTS motor memory)
**A
.Perform a power cut in the following sequence:
1. Power-off - 2 sec. minimum
2. Power-on - 5 to 15 seconds
3. Power-off - 2 sec. minimum
4. Power-on
The end product moves for 5 seconds in one
direction, to indicate that the double power cut has
been recorded. The motor is in PROGRAMMING
STAT for 2 minutes.
E
B
Restoring Factory Mode
.
Press and HOLD the programming button of the NEW RTS
transmitter for more than 7 seconds. The end-product will jog
briefly UP/DOWN twice. Once after 1 second and again after 7
seconds. This indicates the ALTUS/OREA RTS motor has been
completely cleared.
Altus RTS and Orea RTS Motor
Programming and Limit Setting Instructions
with a Previously Recorded Transmitter
!
>5 sec.
**RESETTING MOTORS BACK TO USER MODE
WARNING:
the ALTUS RTS motors on the same power line.
To avoid resetting of non-concerned motors,
press briefly any button of their assigned
transmitter/channel (UP, STOP, or DOWN).
The non-concerned motors will return to USER
MODE.
PREVIOUSLY RECORDED TRANSMITTER
!
>5 sec.
70

NEW TRANSMITTER

5 seconds
This type of power cut affects all
5 seconds

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Orea rts