16

Diagnostic LEDs

There are three diagnostic LEDs located on the carriage front panel.
Figure 7
LED Status
LEDs
Middle and right LEDs on
Middle and left LEDs on
Middle LED on
All LEDS off
All LEDs on
K2 Stairlift Owner's Manual
LH OBSTRUCTION (OR READY TO RUN RIGHT)
RH OBSTRUCTION (OR READY TO RUN LEFT)
OBSTRUCTION, BOTH RH AND LH
SAFETY CIRCUIT FAULT (SEE OWNER'S MANUAL)
READY TO RUN LEFT OR RIGHT
Meaning
Left-hand obstruction (or ready to run right)
Right-hand obstruction (or ready to run left)
Obstruction, both right-hand and left-hand
Safety circuit fault
Ready to run left or right