USA & Canada Official Sales & Service https://www.R-Com-Hatcher.com
3. MARU Function Settings /
4. Optional Functions
Alerting function when the door is open
▶ If the door is open for over 30 seconds during operation,
the "Door Opened" icon pops up with alerting sounds.
The icon disappears immediately if the door is closed.
The Abnormal Low Alarm Settings
▶ WHAT is an abnormal temperature alerting function?
It is a function that alerts the user to an abnormally high
or low temperature inside the incubator.
▶
When incubator temperature is different from setting
value, icon is changed
current temp. and temp. difference alternatively.
The alerting sounds set off for 1 minute and automati
cally stops. The alerting sign stays on until the jog dial
is pressed.
[ How to Set Abnormal High Temp. Setting ]
: When incubator temp. is higher than setting temp.
▶
Setting Range: 0.0℃ ~ 5.0℃, Default Setting : 2.0℃
▶ Press the jog dial for 3 seconds to see the menu and turn
the dial to the left and right to select "Option". Then, press
it again to enter the option mode.
▶ On the option mode, turn the jog dial to the left and right
to select "High Temp. Set", and press the jog dial to enter
the "High Temp. Set" mode. Then, adjust the setting by
turning the jog dial to the left and right. Now, press the
jog dial to save the settings.
[ How to Set Abnormal Low Temp. Setting ]
: When incubator temp. is lower than setting temp.
▶ Setting Range: 0.0℃ ~ - 5.0℃, Default Setting : - 3.0℃
▶ Press the jog dial for 3 seconds to see the menu and turn
the dial to the left and right to select "Option". Then, press
it again to enter the option mode.
▶ On the option mode, turn the jog dial to the left and right
to select "Low Temp. Set", and press the jog dial to enter
the "Low Temp. Set" mode. Then, adjust the setting by
turning the jog dial to the left and right. Now, press the
dial to save the settings.
18
Egg Incubator Hatcher Maru Pro User Manual
(8) Water Shortage Detecting Function /
Power Failure Alarm Function / Alerting function
when the door is open (1) The Abnormal Low Alarm Settings
(Option function)
, and display indicates
Chicken
Close door
37.5
60
45
90˚
Chicken
Chicken
39.5
60
60
90 ˚
45
90 ˚
When temp. difference is 2℃, it indicates 39.5℃ and +2.0
alternatively ( setting 37.5℃)
When temp. difference is -3℃, it indicates 34.5℃ and -3.0
alternatively ( setting 37.5℃)
Option
Auto
Manual
Option
H.CAL
High Error
Parameter saved
High Temp. Error
over
3.0˚C
Option
High
Temp
Auto
Manual
Option
HiErr
Low Error
Parameter saved
Low Temp. Error
over
-4.0˚C
DIGITAL INCUBATOR
+ 2.0
45
High Temp. Set
High
Low
Temp
Temp
HiErr
LoErr
Low Temp. Set
Low
Temp
LoErr
Unit
Need help?
Do you have a question about the MARU DELUXE PRO Series and is the answer not in the manual?