2.5 WIRED SAFETY DEVICE CONNECTIONS
Infrared (IR) safety edge
12 13 14 15 16 17 18 19 20 21 22 23
12 13 14 15 16 17 18 19 20 21 22 23
COM
N.C.
-
If no wired safety edge is used, connect a 8K2 resistor between terminals 16 and 17.
+
12 13 14 15 16 17 18 19 20 21 22 23
12 13 14 15 16 17 18 19 20 21 22 23
8K2
COM
N.C.
-
+
12 13 14 15 16 17 18 19 20 21 22 23
8K2
16- BROWN
17- GREEN
18- WHITE
REFLEX
12Vdc - 15Vdc
REFLEX
12Vdc - 15Vdc
8.2Kohm resistive safety edge
12 13 14 15 16 17 18 19 20 21 22 23
12 13 14 15 16 17 18 19 20 21 22 23
RX FTC010
0V
12V
24V
N.O.
COM
N.C.
NO WIRED SAFETY DEVICE CONNECTED
Connect a 8K2 resistor between terminals 16 and 17.
12 13 14 15 16 17 18 19 20 21 22 23
Terminals 21 and 22 must be closed by a jumper.
RX FTC010
0V
12V
24V
N.O.
COM
N.C.
8
0V
12V
8K2
24V
TX FTC010
0V
12V
24V
TX FTC010

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TVRPS868E01 and is the answer not in the manual?

Questions and answers

David Allen
March 6, 2025

Door opens no problem, door will not close, have to wind it down manually.

1 comments:
Mr. Anderson
March 6, 2025

The TELECO AUTOMATION TVRPS868E01 door may open but not close automatically due to the safety edge being activated or defective. If the floor is uneven, the safety edge can be deactivated using procedure 3.2 in the last part of the closure. Additionally, for the closure to be effective, the command must start from the upper limit switch. If safety devices (except for TB input) are defective or activated, the door can still be operated by holding the command button for more than 5 seconds, switching the control unit to hold-to-run mode.

This answer is automatically generated

Table of Contents

Save PDF