Removing The Front Bezel; Remove A Faulted Drive - Dell EMC PowerStore T Installation And Service Manual

Table of Contents

Advertisement

Faulted parts appear in red in the image of the system, and report a status of Faulted in the State field.
4. Click Blink LED.
The amber fault light on the drive starts blinking.

Removing the front bezel

About this task
NOTE:
Remove the front bezel of the expansion enclosure to gain access to the drives. The bezel is required for EMI
compliance when the enclosure is powered up. Remove it only to replace or add a drive.
Steps
1. If the bezel has a lock, insert the key that shipped with your enclosure into the lock, and turn the key to unlock the bezel.
2. Press the two latch buttons on the bezel surface to release the bezel from the cabinet.
3. Pull the bezel off the cabinet, and put it on a clean, static-free surface.
Figure 121. Removing the front bezel

Remove a faulted drive

Steps
1. Locate the drive with the blinking amber LED fault light.
2. Push down the orange button to release the latch.
3. Remove the drive from the slot.
CL5261
Expansion enclosure service procedures
85