Figure 49. Installing an SFP module
3. Push the spring release down to lock the SFP module into place.
4. Reconnect the cable to the replacement SFP module.
Example

Verify the operation of a replacement part

Steps
1. From PowerStore Manager, select Hardware.
2. Select the appliance where you replaced the faulted part.
3. From the Hardware card, select the view of the system where the part was replaced.
The status of the replacement part should read Healthy. If the status is still Faulted, wait a few minutes and refresh PowerStore
Manager. If the status does not change, ensure that the part is correctly seated, or contact your service provider.

Replace an I/O module

Take the following actions to remove the faulted I/O module and install the replacement I/O module into the system.

Identify a faulted part from PowerStore Manager

Before you replace a part, ensure that you have identified its location within the system. Using PowerStore Manager, you can identify and
locate a faulted part.
Steps
1. From PowerStore Manager, select Hardware.
2. Select the appliance that contains the faulted part.
3. From the Hardware card, select the view of the system where the faulted part is located.
Faulted parts appear in red in the image of the system, and report a status of Faulted in the State field.

Base enclosure I/O module LEDs

Use the fault LEDs to identify the faulted part.
NOTE:
The ports look different depending on whether they are for copper or optical connections. The image below
shows ports for copper cables.
EMC3550
Base enclosure service procedures