A.2 Mutual Exclusion of Functions
A.2.1 Unable to Enter Registration Mode
Fault Description:
Click the panel function key, and prompt key invalid.
Solution:
The panel is in "AP" mode. Switch the panel to "station" mode,
and then try to enter the registration mode again.
A.2.2 Unable to Enter RF Signal Query Mode
Fault Description:
Double-click the host function key, and the prompt button invalid.
Solution:
The panel is in "AP" mode. Solution: switch the panel to "station"
mode, and then try to enter the RF signal query mode again.
A.3 Zone Fault
A.3.1 Zone is Offline
Fault Description:
View status of zones which displays offline.
Solution:
Check whether the detector reports undervoltage. Replace the
detector battery
A.3.2 Zone Tamper-proof
Fault Description:
View status of zones which displays tamper-proof.
Solution:
Recovery detector tamper-proof button.
A.3.3 Zone Triggered/Fault
Fault Description:
View status of zones which displays triggered/fault.
Solution:
Reset the detector.
A.4 Problems While Arming
A.4.1 Failure in Arming (When the Arming Process
is Not Started)
Fault Description:
When the panel is arming, prompt arming fails.
Solution:
The panel does not enable "forced arming", and when there is a
fault in the zone, the arming will fail. Please turn on the "forced
arming" enable, or restore the zone to the normal status.
A.5 Operational Failure
A.5.1 Failed to Enter the Test Mode
Fault Description:
Failed to enable test mode, prompting "A fault in the zone".
Solution: