Arming with Fault
While the arming is stopped with fault, user in level 2 has the
permission to arm the system with fault (forced arming).
Fored arming only taks effect on the current arming operation.
The forced arming operation will be record in the event log.

2.2.2 Disarming

You can disarm the system with keyfob, card, client software, or
mobile client.
Diarming Indication
The arming/disarming indicator flashes 30s while the user
successfully disarm the system through the entry/exit route.
The system will report the disarming result after the operation
completed.
Entry Delay Duration
Set the entry delay duration within 45s to compliant the EN
requirement.
Early Aalrm
If either the intrusion or tampering alalrm occurrs on the enter/
exit route when the control panel is in the status of entry delay,
the control panel then enters the early alarm mode.
The early alarm duration can be set (> 30s).
The control panel will reports the alarm only if the alarm event
lasts over the duration of early alarm with the addition of enry
delay.

2.2.3 Use the Keyfob

The keyfod is used for away arming, stay arming, disarming, panic
alarm, and clearing alarm.