HIKVISION DS-PHA20-P User Manual

HIKVISION DS-PHA20-P User Manual

Hybrid security control panel
Hide thumbs Also See for DS-PHA20-P:
Table of Contents

Advertisement

Hybrid Security Control Panel
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DS-PHA20-P and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for HIKVISION DS-PHA20-P

  • Page 1 Hybrid Security Control Panel User Manual...
  • Page 2 WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES,...
  • Page 3 Hybrid Security Control Panel User Manual PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES. IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER PREVAILS.
  • Page 4 Hybrid Security Control Panel User Manual Symbol Conventions The symbols that may be found in this document are defined as follows. Symbol Description Indicates a hazardous situation which, if not avoided, will or could Danger result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could Caution result in equipment damage, data loss, performance degradation, or...
  • Page 5: Table Of Contents

    Hybrid Security Control Panel User Manual Contents Chapter 1 System Description ..................... 1 Chapter 2 Specifications ......................2 Chapter 3 Activation ........................5 3.1 Activate Device via Web Browser ..................5 3.2 Activate Device via Client Software ..................5 3.3 Activate via SADP ........................6 Chapter 4 Configuration ......................
  • Page 6 Hybrid Security Control Panel User Manual 4.3.9 Arm/Disarm the Zone ....................62 4.3.10 Bypass Zone ......................64 4.3.11 Set Zone ........................65 4.3.12 Set Arming/Disarming Schedule ................66 4.3.13 Check System Status (Zone Status/Communication Status) ........68 4.3.14 Check Alarm Notification ..................69 4.3.15 Set Network Camera Channel ...................
  • Page 7 Hybrid Security Control Panel User Manual A.1.2 Web Page is Not Accessible ..................87 A.1.3 Hik-Connect is Offline ....................87 A.1.4 Network Camera Drops off Frequently ............... 87 A.1.5 Failed to Add Device on APP ..................87 A.1.6 Alarm Information is Not Reported to APP/4200/Alarm Center ......... 88 A.2 Mutual Exclusion of Functions .....................
  • Page 8 Hybrid Security Control Panel User Manual Appendix E. Access Levels ......................98 Appendix F. SIA and CID Code ....................100...
  • Page 9: Chapter 1 System Description

    Hybrid Security Control Panel User Manual Chapter 1 System Description Hybrid security control panel, containing onboard zones, supports wired/wireless alarm inputs and outputs expanding. It works with Wi-Fi, LAN, GPRS, and 3G/ 4G communication methods, as well as ISAPI, Ehome 5.0, and DC09 protocol. It is applicable to the scenarios of market, store, house, factory, warehouse, office, etc.
  • Page 10: Chapter 2 Specifications

    Hybrid Security Control Panel User Manual Chapter 2 Specifications Model DS-PHA20-P DS-PHA20-W2M DS-PHA20-M DS-PHA20-W2P DS-PHA64-M DS-PHA64-W4M Device connection Wireless Detector Up to 16/56 Wireless Output Up to 8 expander Siren 1 wired siren (on-board connection) 2 wireless sirens Keyfob Alarm input...
  • Page 11 Hybrid Security Control Panel User Manual Model DS-PHA20-P DS-PHA20-W2M DS-PHA20-M DS-PHA20-W2P DS-PHA64-M DS-PHA64-W4M Network Wired network 10M/100M Ethernet Cellular Network Supports report push-​ n otification to ARC & Cloud (with 3G/4G/GPRS module) Wi-Fi Standard 802.11b/g/n Encryption 64/128-bit WEP,WPA/ WPA2,WPA-PSK/WPA2- Configuration...
  • Page 12 Hybrid Security Control Panel User Manual Model DS-PHA20-P DS-PHA20-W2M DS-PHA20-M DS-PHA20-W2P DS-PHA64-M DS-PHA64-W4M RS-485 Device Output Plastic Case: 7.2W, current: 600mA Power Metal Case: 13W, current: 1000mA Alarm Output Rated 500 mA Current Operation –10 °C to 55 °C (-4 °F to +122 °F)
  • Page 13: Chapter 3 Activation

    • Get the iVMS-4200 client software from the supplied disk or the official website http:// www.hikvision.com/en/ . Install the software by following the prompts. • The device and the PC that runs the software should be in the same subnet.
  • Page 14: Activate Via Sadp

    • Get the SADP software from the supplied disk or the official website http:// www.hikvision.com/en/ , and install the SADP according to the prompts. • The device and the PC that runs the SADP tool should be within the same subnet.
  • Page 15 Hybrid Security Control Panel User Manual Steps 1. Run the SADP software and search the online devices. 2. Find and select your device in online device list. 3. Input new password (admin password) and confirm the password. Caution STRONG PASSWORD RECOMMENDED-We highly recommend you create a strong password of your own choosing (using a minimum of 8 characters, including upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product.
  • Page 16: Chapter 4 Configuration

    Hybrid Security Control Panel User Manual Chapter 4 Configuration Configure the security control panel in the web client or the remote configuration page in client software. 4.1 Use the Client Software Steps 1. Download, install and register to the client software. 2.
  • Page 17: Communication Settings

    Hybrid Security Control Panel User Manual 4.2.1 Communication Settings Wired Network If the device is linked to the wired network, you can set the wired network parameters when you want to change the device IP address and other network parameters. Steps Note The function is not supported by some device models.
  • Page 18 Hybrid Security Control Panel User Manual 6. Click Save. Wi-Fi You can set the Wi-Fi parameters if there are secure and credible Wi-Fi networks nearby. Steps 1. Click Communication Parameters → Wi-Fi to enter the Wi-Fi page. Figure 4-2 Wi-Fi Settings Page 2.
  • Page 19 Hybrid Security Control Panel User Manual Figure 4-3 WLAN Settings Page 4. Set IP Address, Subnet Mask, Gateway Address, and DNS Server Address. Note If enable DHCP, the device will gain the Wi-Fi parameters automatically. 5. Click Save. Cellular Network Set the cellular network parameters if you insert a SIM card inside the device.
  • Page 20 Hybrid Security Control Panel User Manual Figure 4-4 Cellular Data Network Settings Page 2. Enable Wireless Dial. 3. Set the cellular data network parameters. Access Number Input the operator dialing number. User Name Ask the network carrier and input the user name. Access Password Ask the network carrier and input the password.
  • Page 21 Hybrid Security Control Panel User Manual Alarm Center You can set the alarm center's parameters and all alarms will be sent to the configured alarm center. Steps 1. Click Communication Parameters → Alarm Receiving Center to enter the Alarm Receiving Center page.
  • Page 22 Hybrid Security Control Panel User Manual - ADM-CID or SIA-DCS You should select the Alarm Receiver Type as IP or Domain name, and enter the IP/domain name, port number, account code, timeout, re-upload times and heartbeat interval. Figure 4-6 SIA-DCS Note Set the heartbeat interval with the range from 10 to 3888000 seconds.
  • Page 23 Hybrid Security Control Panel User Manual Figure 4-7 EHome - *SIA-DCS or *ADM-CID You should select the Alarm Receiver Type as IP or Domain name, and enter the IP/domain name, port number, account code, retry timeout period , attempts, heartbeat interval, encryption arithmetic, password length and secret key.
  • Page 24 Hybrid Security Control Panel User Manual Note Set the heartbeat interval with the range from 10 to 3888000 seconds. For encryption arithmetic: The panel support encryption format for information security according to DC-09, AES-128, AES-192 and AES-256 are supported when you configure the alarm center.
  • Page 25 Hybrid Security Control Panel User Manual The device will push notifications when the user operate the control panel. Control Panel System Status Notification The device will push notifications when the control panel system status is changed. Detector Status Notification The device will push notifications when any detector status is changed. Device Status Notification The device will push notifications when any device status is changed.
  • Page 26 Hybrid Security Control Panel User Manual Figure 4-9 Mobile Phone Settings Page 1) Set the Mobile Phone Index and Mobile Phone Number . 2) Check Voice Call on Telephone page. 3) select time of Zoom Alarm and Tampering Alarm Notification Filtering and Number of Calling.
  • Page 27 Hybrid Security Control Panel User Manual Result Note You can arm/disarm/clear alarm via sending SMS. The number of the SIM card installed in the control panel is the receiver number. You can send help to the control panel to get the SMS command list. The control message is Command + Operation Type + Target , and the details are show below.
  • Page 28 Hybrid Security Control Panel User Manual Figure 4-10 Hik-Connect Registration Settings Page 2. Check Register to Hik-Connect. Note By default, the device Hik-Connect service is enabled. You can view the device status in the Hik-Connect server (www.hik-connect.com). 3. Enable Custom Server Address. The server address is already displayed in the Server Address text box.
  • Page 29 Hybrid Security Control Panel User Manual The system will select cellular data network only. 5. Optional: Change the authentication password. Note • By default, the authentication password is displayed in the text box. • The authentication password should contain 6 to 12 letters or digits. For security reasons, an 8-character password is suggested, which containing two or more of the following character types: uppercases, lowercases, and digits.
  • Page 30 Hybrid Security Control Panel User Manual 5. Enter the port number for the protocol. Note By default, the port number for EHome is 7660. 6. Set an account, including the Device ID and EHome Login Password. 7. Select Communication Mode. Auto The system will select the communication mode automatically according to the sequence of, wired network, Wi-Fi network, and cellular data network.
  • Page 31 Hybrid Security Control Panel User Manual Figure 4-12 NAT Settings 2. Drag the slider to enable UPnP. 3. Optional: Select the mapping type as Manual 4. Set the HTTP port and the service port. 5. Click Save to complete the settings Set FTP to Save Video You can configure the FTP server to save alarm video.
  • Page 32: Device Management

    Hybrid Security Control Panel User Manual Figure 4-13 FTP Settings 2. Select FTP Type. 3. Drag the slider to enable FTP. 4. Select address type as Domain Name or IP. 5. Enter the domain name or FTP server. 6. Enter port number, user name and password. 7.
  • Page 33 Hybrid Security Control Panel User Manual Figure 4-14 Wired Zone Settings 2. Edit the zone name. 3. Select a zone type. Instant Zone This Zone type will immediately trigger an alarm event when armed. Delayed Zone Exit Delay: Exit Delay provides you time to leave through the defense area without alarm. Entry Delay: Entry Delay provides you time to enter the defense area to disarm the system without alarm.
  • Page 34 Hybrid Security Control Panel User Manual Perimeter Zone The system will immediately alarm when it detects a triggering event after the system is armed. There is a configurable interval timer between the alarm activation and siren output "Siren Delay Time (Perimeter Alarm) 0 to 600 Seconds". This option allows you to check the alarm and cancel the siren output during the interval time in case of false alarm.
  • Page 35 Hybrid Security Control Panel User Manual Note The resistor wired on the on-board zone should be the same as the resistor configured on this page. 5. Select a detector type. 6. Enable Stay Arming Bypass, Silent Alarm or Dual-Zone Settings according to your actual needs. Note Some zones do not support the function.
  • Page 36 Hybrid Security Control Panel User Manual Figure 4-15 Wireless Zone Settings 2. Edit the zone name. 3. Select a zone type. For details, see Wired Zone Settings. 4. Enable Stay Arming Bypass, Silent Alarm and Enroll Wireless Detector. 5. Enter the serial No. to enroll the detector. 6.
  • Page 37 Hybrid Security Control Panel User Manual Siren The siren is enrolled to the control panel via the wireless receiver module, and the 868 Mhz wireless siren can be enrolled to the hybrid control panel via the wireless receiver that is at the address of 9.
  • Page 38 Hybrid Security Control Panel User Manual Note The siren in 868 MHZ may not support this function. 6. Set the Disconnection Time, and the system determines connection fault if the disconnected duration of the device is longer than the configured value. 7.
  • Page 39 Hybrid Security Control Panel User Manual 4. Set the module name. 5. Enable Enroll Wireless Repeater and entert the repeater serial No. 6. Click OK. Note After setting the repeater, you can enter Status → Repeater to view the repeater status. Relay If you want to the link the device with a relay output to output the alarm, set the output parameters.
  • Page 40: Partition Settings

    Hybrid Security Control Panel User Manual Keypad The keypad is connected to the control panel via RS-485 wiring. You can refer to Hybrid Control Panel Quick Start Guide for wiring details. Steps 1. Click Control Device → Keypad to enter the page. 2.
  • Page 41 Hybrid Security Control Panel User Manual Figure 4-20 Partition Basic Information Management Page 2. Select a partition. 3. Check the Enable One-Push Arming to enable the One-Push Arming key on the keypad. 4. Check the check box in front of the zone to select zones for the partition. 5.
  • Page 42 Hybrid Security Control Panel User Manual Figure 4-21 Public Partition Settings 2. Check the checkbox to enable the public partition function. Note the default public partition is partition 1 3. Select partition(s) to link to the public partition in the list. Note It is required to select at least a partition to link to the public paritition.
  • Page 43 Hybrid Security Control Panel User Manual Figure 4-22 Schedule & Timer Settings 2. Select a partition. 3. Set time duration of Entry Delay 1, Entry Delay 2, or Exit Delay respectively. Entry Delay 1/Entry Delay 2 If you have set the entry delayed zone, you can set the delayed time duration here. Note The available time duration range is from 1 s to 600 s.
  • Page 44 Hybrid Security Control Panel User Manual 4. Optional: Set the following parameters according to actual needs. Enable Auto Arming Enable the function and set the arming start time. The zone will be armed according to the configured time. Note • The auto arming time and the auto disarming time cannot be the same. •...
  • Page 45: Video Management

    Hybrid Security Control Panel User Manual Note The available time duration range is from 0 s to 600 s. Alarm Duration If you have set the perimeter zone, you can set the time duration of the alarm. Note The available time duration range is from 1 s to 900 s. 5.
  • Page 46 Hybrid Security Control Panel User Manual Note You can add thermal cameras. After the relevant functions are configured, when the temperature is abnormal, the system will upload the alarm. 5. Optional: Click Edit or Deleteto edit or delete the selected camera. Link a Camera with the Zone Steps 1.
  • Page 47 Hybrid Security Control Panel User Manual Note It is recommended to use Gmail and Hotmail for sending mails. 4. Enter the receiver's information. 5. Click Receiver Address Test and make sure the address is correct. 6. Click Save. Set Video Parameters Steps 1.
  • Page 48: Permission Management

    Hybrid Security Control Panel User Manual The higher value corresponds to the higher video quality, but the better bandwidth is required. 4.2.5 Permission Management Add/Edit/Delete User Administrator can add user to the security control panel, edit the user information, or delete the user from the security control panel.
  • Page 49 Hybrid Security Control Panel User Manual Figure 4-26 Add User Page 5. Set the keypad password (numeric, 8~16 characters). Note The keypad password +1 or -1 is the duress code. Use the duress code can operate the keyboard to arm and disarm normally and upload a duress alarm. For example, if the keypad password is 123456, the duress code is 123455 or 123457 6.
  • Page 50 Hybrid Security Control Panel User Manual Add/Edit/Delete Keyfob You can add keyfob to the security control panel and you can control the security control panel via the keyfob. You can also edit the keyfob information or delete the keyfob from the security control panel.
  • Page 51: Maintenance

    Hybrid Security Control Panel User Manual Figure 4-28 Card Management 2. Click Add to enter the adding page. 3. Select the linked keypad. 4. Click OK and the card information will be displayed in the list. Note The card supports at least 20-thousand serial numbers. 5.
  • Page 52 Hybrid Security Control Panel User Manual 2. Check the Test check box to start walk test. 3. Click Save to complete the settings. 4. Trigger the detector in each zone. 5. Check the test result. Diagnosis The control panel supports diagnosis of system, alarm, wireless device, Wi-Fi, and cloud platform Steps 1.
  • Page 53: System Settings

    Hybrid Security Control Panel User Manual Figure 4-29 Export File Page 2. Enable Debugging Log. 3. Click Export to save the debugging file in the PC. 4.2.7 System Settings Device infomration You can change name and lanuage of device. Click System → Device Information to enter the page. Figure 4-30 Device Information You can set the device name or change the device language.
  • Page 54 Hybrid Security Control Panel User Manual Note After changing the device language, the device will reboot. You can view device model, device serial No., device firmware version, web version or click About → View Licenses to view the source software licenses. Authority Management Set the authority options.
  • Page 55 Hybrid Security Control Panel User Manual Check the faults in the Enable Arming with Fault list, and the device will not stop the arming procedure when faults occurred. Arming Indicator Keeps Light If the device applies EN standard, by default, the function is disabled. In this case, if the device is armed, the indicator will be solid blue for 5 s.
  • Page 56 Hybrid Security Control Panel User Manual If the option is enabled, when the wired network is disconnected or with other faults, the alarm will be triggered. Wi-Fi Fault Check If the option is enabled, when the Wi-Fi is disconnected or with other faults, the alarm will be triggered.
  • Page 57 Hybrid Security Control Panel User Manual Time Settings You can set the device time zone, synchronize device time, and set the DST time. The device supports time synchronization via Hik-Connect server. Time Management Click System → Date and Time to enter the Time Management page. You can select a time zone from the drop-down list.
  • Page 58 Hybrid Security Control Panel User Manual Steps 1. Click System → Security → Locking User Settings to enter the Locking User Settings page. 2. Set the following parameters. Max. Failure Attempts If the user continuously input the incorrect password for more than the configured times, the account will be locked.
  • Page 59 Hybrid Security Control Panel User Manual Figure 4-34 Module Lock Settings System Maintenance You can reboot the device, restore default settings, import/export configuration file, or upgrade the device remotely. Select the device and click in the client software, or enter the device IP address in the address bar of the web browser.
  • Page 60: Check Status

    Hybrid Security Control Panel User Manual Local Log Search You can search the log on the device. Click System → Log to enter the Local Log Search page. Figure 4-36 Local Log Search Page Select a major type and a minor type from the drop-down list, set the log start time and end time and click Filter.
  • Page 61: Use Mobile Client

    Hybrid Security Control Panel User Manual 4.3 Use Mobile Client 4.3.1 Download and Login the Mobile Client Download the Hik-Connect mobile client from Google Play (for Android) or App store (for iOS) and login the client before operating the security control panel. Steps 1.
  • Page 62: Add Control Panel To The Mobile Client

    Hybrid Security Control Panel User Manual Note You need to remove the rear panel of the device and the AP/STA switch is on the back of the device. 8. Select a stable Wi-Fi for the device to connect and tap Next. Note Make sure the device and the mobile phone are connect to the same Wi-Fi.
  • Page 63: Add Peripheral To The Control Panel

    Hybrid Security Control Panel User Manual Note Normally, the QR code is printed on the label stuck on the back cover of the control panel. - Tap → Manual Adding to enter the Add Device page. Enter the device serial No. with the Hik-Connect Domain adding type.
  • Page 64: Add Card

    Hybrid Security Control Panel User Manual Note The QR code is usually on the back cover of the device. 4. Optional: If the QR code fails to be recognized, tap and enter the serial number of the device, and then select the device type. Note The serial number is usually on the back cover of the device.
  • Page 65: Add Keyfob

    Hybrid Security Control Panel User Manual Figure 4-38 Partition Page 2. Tap → User Management → Card/Tag Management to enter the Card/Tag Management page. 3. Tap +. 4. When hearing the voice prompt "Swipe Card", you should present the card on the control panel card presenting area.
  • Page 66: User Management

    Hybrid Security Control Panel User Manual 2. Tap to enter the Scan QR Code page. 3. Tap Add Keyfob. 4. Follow the instruction on the page and press any key on the keyfob to add. 5. Create a name for the keyfob and tap Finish. The keyfob is listed in the Wireless Device page.
  • Page 67: System Settings

    Hybrid Security Control Panel User Manual Figure 4-40 Add User 4. Select User Type. Enter User Name and Password. 5. Enter Keypad Password. Note The keypad password +1 or -1 is the duress code. Use the duress code can operate the keyboard to arm and disarm normally and upload a duress alarm.
  • Page 68 Hybrid Security Control Panel User Manual Figure 4-41 Option Managment Wireless Device Supervision If the option is enabled, the system will detect status of all wireless devices. System Fault Report If the option is enabled, the device will upload report automatically when there is system faults. Disable Function Key If the option is enabled, all function keys will be disabled.
  • Page 69 Hybrid Security Control Panel User Manual Figure 4-42 Fault Check Detect Network Camera Disconnection If the option is enabled, when the linked network camera is disconnected, an alarm will be triggered. Panel Battery Fault Check If the option is enabled, when battery is disconnected or out of charge, the device will upload events.
  • Page 70: Arm/Disarm The Zone

    Hybrid Security Control Panel User Manual System Maintenance On the device list page, tap the security control panel and then log in to the device (if required) to enter the control panel page. → System Maintenance to set parameters. Reboot Device The device will restore all parameters to the default settings.
  • Page 71 Hybrid Security Control Panel User Manual Figure 4-44 Partition Page Operations for a Single Partition • Away: When all the people in the detection area leave, turn on the Away mode to arm all zones in the partition after the defined dwell time. •...
  • Page 72: Bypass Zone

    Hybrid Security Control Panel User Manual 4.3.10 Bypass Zone When the partition is armed, you can bypass a particular zone as you desired. Before You Start Link a detector to the zone. Steps 1. On the device list page, tap the security control panel and then log in to the device (if required) to enter the Partition page.
  • Page 73: Set Zone

    Hybrid Security Control Panel User Manual 4.3.11 Set Zone After the detector is added, you can set the zone, including the zone name, the zone type, zone bypass, linked camera, stay/away status, the siren, and the silent zone. You can also view the detector serial No.
  • Page 74: Set Arming/Disarming Schedule

    Hybrid Security Control Panel User Manual If you select Timeout Zone, you should select a timeout value or tap Custom to set a custom value. Zone Bypass Enable the function and the zone will be bypassed. No alarm will be received while the zone is bypassed.
  • Page 75 Hybrid Security Control Panel User Manual Figure 4-47 Arming or Disarming Schedule Page Entry Delay 1 Entry Delay 2 Set a value for Entry Delay 1 and Entry Delay2. Entry delay is a time concept. If entry delay is configured for the delayed zone, when you enter an armed delayed zone, the zone alarm will not be triggered until the end of entry delay.
  • Page 76: Check System Status (Zone Status/Communication Status)

    Hybrid Security Control Panel User Manual Enable the partition to automatically arm itself in a specific time point. Auto Arm Time Set the schedule for the partition to automatically arm itself. Late to Disarm Enable the device to push a notification to the phone or tablet to remind the user to disarm the partition when the partition is still armed after a specific time point.
  • Page 77: Check Alarm Notification

    Hybrid Security Control Panel User Manual EN Mode the Partition page, tap to enter the page. Slide to enable EN Mode. Note The device will be auto rebooted when you turn on or turn off EN Mode. 4.3.14 Check Alarm Notification When an alarm is triggered, and you will receive an alarm notification.
  • Page 78: Set Network Camera Channel

    Hybrid Security Control Panel User Manual Figure 4-49 Alarm Details 3. Optional: If the zone has linked a camera, you can view the playback when the alarm is triggered. 4.3.15 Set Network Camera Channel Steps 1. On the device list page, tap the security control panel and then log in to the device (if required) to enter the control panel page.
  • Page 79: Set Event Video Settings

    Hybrid Security Control Panel User Manual 4. Enter IP Address, Port, User Name and Password. 5. Tap to add channel. 6. Optional: Edit a channel. 1) Select a channel in the list. Figure 4-51 Network Camera Settings 2) Tap to enetr the editing mode. 3) Edit parameters.
  • Page 80: Add A Camera To The Zone

    Hybrid Security Control Panel User Manual Figure 4-52 Event Video Settings Stream Type Main Stream: Being used in recording and HD preview, it has a high resolution, code rate and picture quality. Sub-Stream: It is used to transmit network and preview pictures as a video streaming with features of lower resolution, bit rate and picture quality.
  • Page 81 Hybrid Security Control Panel User Manual Steps 1. On the device list page, tap the security control panel and then log in to the device (if required) to enter the control panel page. 2. Tap Zone to enter the zone list page. 3.
  • Page 82: Chapter 5 Operations

    Hybrid Security Control Panel User Manual Chapter 5 Operations You can use the client keyfob, card, client software, or mobile client to do arming, disarming, bypass, and zone disabling. 5.1 Arming You can use keypad, keyfob, card, client software, mobile client to arm your system. After the arming command is sending to control panel, the sytem will check the detector status.
  • Page 83: Disarming

    Hybrid Security Control Panel User Manual Reason of Arming Failure • Intrusion detector triggered (excepts the detector on the exit route). • Panic alarm device triggered. • Tampering alarm occurred. • Communication exception • Main power supply exception • Backup battery exception •...
  • Page 84 Hybrid Security Control Panel User Manual Figure 5-2 TypeⅠ Keyfob Table 5-1 Type Ⅰ Keyfob Keys Description Indicator Green: Successful Operation Red: Press the Key Away Arming Clearing Alarm Stay Arming Disarming Panic Alarm (Duress Alarm) Hold the key for 2 seconds, an alarm report will be send to the alarm center secretly without alerting.
  • Page 85 Hybrid Security Control Panel User Manual Figure 5-3 Type Ⅱ Keyfob Table 5-2 Type Ⅱ Keyfob Keys Description Arming (Lock) Disarming( Unlock) Combo-​ F unction Key Custom Combination Functions (except Arming +Ⅱ and Disarming +Ⅰ) : Away Arming, Stay Arming, Disarming, Panic Alarm, Clearing Alarm, Fault Inspection, and Arming Status Check. The following table shows the keyfob operation and responded indications.
  • Page 86: Use The Card

    Hybrid Security Control Panel User Manual 5.4 Use the Card It is poissible to arm or disarm the system with the card. While the system is not armed, present a valid card to the control panel to arm the system. While the system is armed, present a valid card to the control panel to disarm the system.
  • Page 87: Add Device To The Client Software Through Cloud P2P

    Hybrid Security Control Panel User Manual The following describes how to add devices through IP/Domain Name. For more information, see iVMS-4200 Client Software User Manual. Steps 1. On the Device page, click Add. 2. Select IP/Domain as the adding mode, edit the device information, including Name, Address, Port, User Name, and Password.
  • Page 88: Partition Operation

    Hybrid Security Control Panel User Manual Figure 5-5 Login Cloud P2P Account Note • If you have added a device to your Cloud P2P account, the device will appear in the device list. If not, you need to add a device via cloud P2P or IP. •...
  • Page 89: Operate The Relay

    Hybrid Security Control Panel User Manual Figure 5-6 Partition Operation Click to enter the zone operation page. You can Bypass and Bypass Recovered the selected zones here. 5.5.4 Operate the Relay In the client software, click Security Control Panel → Relay to enter the page. You can Enable or Close the selected relays.
  • Page 90: Use The Web Client

    Hybrid Security Control Panel User Manual Figure 5-8 Siren Operation 2. You can Enable or Close the selected sirens. 5.6 Use the Web Client Steps 1. Connect the device to the Ethernet. 2. Search the device IP address via the client software and the SADP software. 3.
  • Page 91: Add/Edit/Delete Tag (Card)

    Hybrid Security Control Panel User Manual 5.6.1 Add/Edit/Delete Tag (Card) You can add tag to the security control panel and you can use the tag(card) to arm/disarm the zone. You can also edit the tag information or delete the tag from the security control panel. Steps 1.
  • Page 92: Add/Edit/Delete User

    Hybrid Security Control Panel User Manual Figure 5-10 Keyfob Management 2. Click Add and press any key on the keyfob. 3. Set the keyfob linked device type and linked device No.. 4. Click OK. 5. Optional: Click to edit the keyfob information. 6.
  • Page 93 Hybrid Security Control Panel User Manual Language User Name Language User Name German errichter Portuguese instalador Turkish kurulumcu Czech technik 3. Click Add. 4. Set the new user's information in the pop-up window, including the user type, the user name, and the password.
  • Page 94: Check Status

    Hybrid Security Control Panel User Manual Note The admin, the installer and the manufacture cannot be deleted. 5.6.4 Check Status After setting the zone, repeater, and other parameters, you can view their status. Click Status. You can view the status of zone, relay, siren, battery, communication, and repeater. •...
  • Page 95: Appendix A. Trouble Shooting

    Hybrid Security Control Panel User Manual Appendix A. Trouble Shooting A.1 Communication Fault A.1.1 IP Conflict Fault Description: IP that the panel automatically acquired or set is same as other devices, resulting in IP conflicts. Solution: Search the current available IP through ping. Change the IP address and log in again. A.1.2 Web Page is Not Accessible Fault Description: Use browser to access web pages and display Inaccessible.
  • Page 96: Alarm Information Is Not Reported To App/4200/Alarm Center

    Hybrid Security Control Panel User Manual When using APP to add devices, it is prompted that the device fails to be added, the device could not be found, etc. Solution: Check the web page: whether the Hik-Connect is offline. A.1.6 Alarm Information is Not Reported to APP/4200/Alarm Center Fault Description: After the alarm is triggered, the app/4200/ alarm center does not receive the alarm message.
  • Page 97: Zone Tamper-Proof

    Hybrid Security Control Panel User Manual Solution: Check whether the detector reports undervoltage. Replace the detector battery A.3.2 Zone Tamper-proof Fault Description: View status of zones which displays tamper-proof. Solution: Make tamper-proof button of the detector holden. A.3.3 Zone Triggered/Fault Fault Description: View status of zones which displays triggered/fault.
  • Page 98: The Alarm Clearing Operation On The Panel Does Not Produce The Alarm Clearing

    Hybrid Security Control Panel User Manual A.5.2 The Alarm Clearing Operation on the Panel Does Not Produce the Alarm Clearing Report Fault Description: The alarm clearing operation on the panel does not produce the alarm clearing report. Solution: In the absence of alarm, no report will be uploaded for arm clearing. A.6 Mail Delivery Failure A.6.1 Failed to Send Test Mail Fault Description:...
  • Page 99: Failed To Send Mails To Qq Or Foxmail

    Hybrid Security Control Panel User Manual Solution: Click the link below, and then click "continue" (https://accounts.google.com/b/0/ displayunlockcaptcha). A.6.4 Failed to Send Mails to QQ or Foxmail Fault Description: The receiver's mailbox is QQ or foxmail. Click "Test Inbox" and prompt test fails. 1.
  • Page 100 Hybrid Security Control Panel User Manual Mail Type Mail Server SMTP Port Protocols Supported Sina smtp.sina.com 25/465/587 SSL/TLS/STARTTLS (SSL/TLS) Note About mail configuration: • SMTP port Default to use port 25 without encryption, or using port 465 if SSL/TLS is used. Port 587 is mainly used for STARTTLS protocol mode.
  • Page 101: Appendix B. Input Types

    Hybrid Security Control Panel User Manual Appendix B. Input Types Table B-1 Input Types Input Types Operations Instant Zone The system will immediately alarm when it detects triggering event after system armed. Audible Response Trigger the system sound and siren. Voice Prompt: Zone X alarm.
  • Page 102 Hybrid Security Control Panel User Manual Input Types Operations Gas Zone The zone activates all the time with sound/siren output when alarm occurs. Audible Response: Trigger the system sound and siren. Voice Prompt: Zone X gas alarm. Medical Zone The zone activates all the time with beep confirmation when alarm occurs.
  • Page 103 Hybrid Security Control Panel User Manual Input Types Operations Voice Prompt: Armed/Arming failed.
  • Page 104: Appendix C. Output Types

    Hybrid Security Control Panel User Manual Appendix C. Output Types Table C-1 Output Types Output Types Active Restore Arming Arm the control panel After the configured output delay Disarming Disarm the control panel After the configured output delay Alarm When alarm event occurs. The After the configured output alarm output will be activated delay, disarm the control panel...
  • Page 105: Appendix D. Event Types

    Hybrid Security Control Panel User Manual Appendix D. Event Types Table D-1 Event Types Event Types Custom Default 1 Default 2 Default 3 Default 4 (client (alarm (mobile client) (telephone) software receiving notification) center 1/2) Alarm and ×/√ √ √ √...
  • Page 106 Hybrid Security Control Panel User Manual Appendix E. Access Levels Level Description Access by any person; for example the general public. User access by an operator; for example customers (systems users). User access by an engineer; for example an alarm company professional. User access by the manufacturer of the equipment.
  • Page 107 Hybrid Security Control Panel User Manual • When the controller is bypassed, the user level 3 can login the controller without the permission assignment of the user level 2. • The user level 4 can login the controller only when the user level 2 or level 3 has assigned permissions to the user level 4.
  • Page 108 Hybrid Security Control Panel User Manual Appendix F. SIA and CID Code Table F-1 SIA and CID Code SIA Code CID Code Description E130 Burglary Alarm R130 Burglary Alarm Restored E122 Silent Panic Alarm R122 Silent Panic Alarm Restored E780 Timeout Alarm R780 Timeout Alarm Restored...
  • Page 109 Hybrid Security Control Panel User Manual SIA Code CID Code Description E120 Keypad/Keyfob Panic Alarm E100 Medical Alarm R100 Medical Alarm Restored E151 Gas Leakage Alarm R151 Gas Leakage Alarm Restored E110 Fire Alarm R110 Fire Alarm Restored E401 Disarming R401 Away Arming E403...
  • Page 110 Hybrid Security Control Panel User Manual SIA Code CID Code Description E305 Control Panel Reset E321 Wireless Siren Disconnected R321 Wireless Siren Connected E381 Wireless Detector Disconnected R381 Wireless Detector Connected E384 Wireless Detector Low Voltage R384 Normal Wireless Detector Voltage E333 Expander or Wireless Device...
  • Page 111 Hybrid Security Control Panel User Manual SIA Code CID Code Description E306 Expander Deleted R306 Expander Added E306 Detector Deleted R306 Detector Added E306 Wireless Repeater Deleted R306 Wireless Repeater Added E306 Wireless Siren Deleted R306 Wireless Siren Added E130 Burglary Alarm R130 Burglary Alarm Restored...
  • Page 112 Hybrid Security Control Panel User Manual SIA Code CID Code Description 1409 Key Zone Disarm 3409 Key Zone Arm 1131 Intrusion Detection Alarm 3131 Intrusion Detection Alarm Restore 1131 Line Crossing Alarm 3131 Line Crossing Alarm 1134 Region Entrance Detection 1112 Fire Detection Alarm 3112...

Table of Contents