Servo Drive Main Circuit Wiring; Main Circuit Terminals - Inovance SV820N Series Manual

Table of Contents

Advertisement

3.1

Servo Drive Main Circuit Wiring

3.1.1

Main Circuit Terminals

Main circuit input terminals of the SV820N multi-axis servo drive
Figure 3-2 Main circuit terminal arrangement
Table 3-1 Names and functions of the main circuit terminals of the SV820N servo drive
Terminal
Terminal Name
Symbol
Main circuit power input
L1, L2, L3
terminals
Control power input
L1C, L2C
terminals
Terminals for connecting
P, C
external bleeder resistor
P, N
Common DC bus terminal
PE
Ground
L1C
L2C
L1
L2
L3
P
C
N
PE
Main circuit single-phase/three-phase 220 V power input. Terminals L1
and L2 are for single-phase power input, and terminals L1, L2 and L3
are for three-phase power input.
Control circuit 220 V AC power input.
When large-inertia load needs braking for emergency stop, connect an
external bleeder resistor between P and C.
The external bleeder resistor needs to be purchased additionally.
They are used for common DC bus connection when multiple servo
drives are under parallel control.
Two grounding terminals of the servo drive are respectively connected
to those of the power supply and the servo motor.
Terminal Function
3 Wiring
3
- 35 -