Put /Permittedmeters - ABB G13 User Manual

Table of Contents

Advertisement

Response
Description
Note
At any time max of 25 serial numbers can be specified
}

6.3.39 PUT /permittedmeters

A PUT call to /permittedmeters adds a new meter to list.
Protected
Yes (Authentication required)
2CMC489001M0201
Revision: A
• 200 OK
HTTP/1.1 200 OK
Content-Type: application/json
Server: embOS/IP
Transfer-Encoding: chunked
Link:/lasterror/0
{
"meters": [
"ABBXXXXXXXXXXXXX1",
"ABBXXXXXXXXXXXXX2",
"ABBXXXXXXXXXXXXX3"
]
}
• meters [Array of serial numbers (string 17)]
• 500 Internal Server Error
HTTP/1.1 500 Internal Server Error
Server: embOS/IP
Accept-Ranges: bytes
Content-Length: 64
Content-Type: application/json
{
"status":"error",
"des":"received invalid response from COSEM."
124
JSON Communication
User Manual
G13

Hide quick links:

Advertisement

Table of Contents
loading