12. Maintenance

Danger to life due to high voltage
Before opening the switch cabinet, the device must be disconnected from the power supply at all
poles. (Disconnect the power plug.)
Live components and connections may be exposed in the process.
Maintenance work may only be performed by trained specialists. Children are not permitted to op-
erate the device under any circumstances.
12.1

Maintenance Intervals

Time period
As necessary
Daily/
prior to commis-
sioning
Weekly
6 months
44
Error 292: Supervision, EL6080 NOVRAM,
fbWrite.bWcState
Error 293: Supervision, EL6080 NOVRAM,
Write: FB busy for t>200ms
Error 294: Supervision, EL6080 NOVRAM,
Load: FB Read/Write busy for t>200ms
Error 295: EL6080 NOVRAM, Cyclic Access
not possible
Error 310: LV-Wedge Controller Error. Restart
Machine
Monitoring and maintenance work
• Clean hot wedge and replace if neces-
sary
• Clean or replace the air filter
• Adjustment of pedestal, quickarm, and
UWM
• Check the stability of the machine
• Check the machine and power cable for
damage
Clean the entire machine with a damp cloth
Clean or replace the filter for the switch cabi-
net. Depending on the ambient conditions.
Invalid Working Counter of EL6080.
Shutdown SEAMTEK W-AT Machine and
restart.
Can not write Meter Hours during Startup of
Supervision Extension. Delete Error Message
in i-Tab. If Error reappears shutdown SEAM-
TEK W-AT Machine and restart.
Can not read Meter Hours during Startup of
Supervision Extension.
Shutdown SEAMTEK W-AT Machine and
restart.
Can not store and load data. Restart machi-
ne if Error is recurrent.
LV-Wedge PID Controller has Error. Restart
Machine.
Replacement parts
Air filter
Filter
Art. 156.762
Tools
Plastic scraper,
brass brush
Damp cloth
Isopropyl alcohol,
compressed air