Seamtek W-At Warning And Error Messages; Error Levels; Error List - Leister SEAMTEK W-AT Series Manual

Table of Contents

Advertisement

11. SEAMTEK W-AT Warning and Error Messages

11.1

Error Levels

Any errors that occur are separated into two levels by the machine control unit. The errors are differentiated on the
basis of their impact on the process, machine, and persons.
Table 1: error differentiation
Error Level
Designatio
1 or
Technical
1xx
warning
2 or
Error:
2xx
Process error
3 or
Error:
3xx
Emergency
11.2

Error List

The error number is shown for the Leister Support team in the information text. Error numbers using a basis of 100
indicate the error level, e.g., 201 is a level 2 error. Error 301 is a level 3 error.
All errors that are trapped and/or signalized by the control unit are then listed.
Table 2: list of all errors
Error No. Level
110
1
111
1
120
1
200
2
201
2
202
2
204
2
205
2
206
2
207
2
208
2
40
Impact
n
No or minor impact on the
process
Significant impact on the
ongoing process.
Immediate
persons or destruction of
components
Info Text
Warning 110: UPWM-Axis: Total Axis Clea-
rance > 10 mm
Warning 111: Heat turned off due to low min
speed
Warning 120: Touch Calibration failed,
ADS Return Code
Error 200: Puller Motor Driver Error
Error 201: Upper Motor Driver Error (Upper
Wheel Module).
Error 202: Lower Motor Driver Error (Pede-
stal or Quickarm)
Error 204: Reading Machine Settings File.
Check Machine Settings. Passwords set to
standard
Error 205: Error Setup X-Axis. g_eStateMa-
chine = INIT
Error 206: Error Setup Y-Axis. g_eStateMa-
chine = INIT
Error 207: Error Setup UPWM-Axis. g_eSta-
teMachine = INIT
Error 208: Cannot open Backup Source File.
Action
Note display in error list. Tab for the information
screen is displayed in red.
Display in error list and tab for the information
screen is displayed in red.
(E.g., axis error)
danger
for
Emergency display on screen; safe shutdown of
system if possible.
Description
Clamp Clearance (UPWM-Axis) is more than
10 mm
Heat turned off due to low min speed
Trouble in calibration procedure of Touch Pa-
nel. Restart machine if warning is recurrent.
Driver error (Puller). Check for Overload.
Driver error (Upper Wheel Module). Check for
Overload.
Beckhoff Treiber Error (Pedestal or Quickarm)
Check for Overload.
In StateMachine()
Machine Settings File can not be read. Stan-
dard Values applied
In StateMachine()
X-Axis initial position can not be reached,
check if X-Axis is mechanically blocked
In StateMachine()
Y-Axis initial position can not be reached,
check if Y-Axis is mechanically blocked
In StateMachine()
UPWM-Axis initial position can not be rea-
ched, check if UPWM-Axis is mechanically
blocked
Recipe File on PLC (SPS) corrupted. Do reco-
ver your Data from your Memory Stick.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Seamtek w-900 atSeamtek w-2000 at

Table of Contents