6
Output connection
Mounting
Retract confirm sensor
Sealing
Storage temperature
Operating temperature
Note 1
When wiring the APC to the machine control the installer should ensure the screen is connected (see pages 10 and 11).
Note 2
Performance specification is tested at a standard test velocity of 480 mm/min (18.9 in/min). Significantly higher velocity is
possible depending on application requirements.
Note 3
Using a 60 mm stylus.
Note 4
Connections:
Product
APCA with or without "air bleed"
APCS
APCS with "air bleed"
Note 5
Can be configured by customer to provide air blast functionality.
Specification (continued)
Blanked DIN EN ISO 228–G 1/8 outlet for customer configurable
"air blast stalk".
M4 × 50 mm (1.97 in) long (ISO 4762 grade 12.9) or equivalent × 4
Operating voltage 12 Vdc to 30 Vdc, no load current 3 mA, rated
operating current 150 mA, output resistance open collector,
switching output PNP normally open (NO). When the cover is
extended, the output is LOW. When the cover is retracted it is
HIGH. (12 Vdc to 30 Vdc).
IPX6 and IPX8, BS EN 60529:1992+A2:2013
(IEC 60529:1989+A1:1999+A2:2013)
Connector sealed to IP67 when mated.
–25 °C to +70 °C (–13 °F to +158 °F)
+5 °C to +55 °C (+41 °F to +131 °F)
Port 1
Retract and "air bleed"
Exhaust
"Air bleed"
Port 2 (see note 5)
Port 3
Air blast
Extend
Air blast
Extend
Air blast
Extend