Troubleshooting
Malfunction
Main switch is on, display is
blank
There is a hissing sound during
operation.
No vacuum and/or compressed
air.
Error messages
Error message
E001
No water
E002
No compressed air
E003
Lock not activated
E010
Generator malfunction
English ⋅ Nautilus
Cause
Device has no power.
Sealing surfaces on crucible
and/or mould door are soiled/
dirty.
Air filter is dirty.
Cause
Add water (→ page 72).
* Ensure compressed air supply ≥ 5 bar (100 l/min) or
switch off other compressed air loads.
Install compressed air reservoir, as needed
(→ page 16).
Clean seals (→ page 74).
* Close doors properly.
Switch the device off!
Check fuses (→ p. 75).
Check induction coil (→ p. 70): Remove any dirt that
has collected between the coil windings
Notify Customer Service.
®
CC plus ⋅ Nautilus
®
The NAUTILUS
-devices issue three types of
messages.
•
Error messages indicate significant errors,
which will abort the casting process.
•
Warnings will not abort the casting process;
after clearing the message (OK button), the
process can be continued. Exception: W001
(insufficient cooling water) and W002 (insuffi-
cient compressed air).
•
Notes refer to general service and mainte-
nance tasks. They are displayed before or after
casting.
General notes on troubleshooting:
1.
Switch the device off (exceptions: see *).
2.
Eliminate the malfunction.
3.
Switch the device on.
4.
Notify Service if messages appear repeatedly.
Service must only be carried out by authorized
BEGO repair shops!
Check power supply connection;
Check fuses (→ p. 75).
Caution! Components are very hot!
Clean seals and sealing surfaces
(→ p. 74).
Replace the air filter (→ p. 77).