English ⋅ Nautilus
The chamber is evacuated during preheating.
The preheating may last for up to 60 seconds.
®
NAUTILUS
alerts the operator with an acous-
tic signal and a message on the display that
the preheating process has ended.
7.
Have the mould readily available before press-
ing the "OK" button to prevent the alloy from
cooling down unnecessarily. Preheating tem-
perature and vacuum are maintained until
then.
WARNING
Risk of burns!
Use mould tongs!
8.
Close the mould door.
The next display is shown when the mould
door is closed.
®