English ⋅ VARSEO XS This device documentation is part of the device and must be enclosed when selling or trans- ferring the device. • The device has been designed solely for use in institutions such as research, commercial and training facilities. The device must only be oper- ated by trained specialists;...
Copyright by BEGO Bremer Goldschlägerei Wilh. Herbst GmbH & Co. KG These operating instructions are protected by copyright. All rights reserved. Reproductions of this document, in whole or in part, require the express written permission of BEGO Bremer Goldschlägerei Wilh. Herbst GmbH & Co. KG !
Page 6
English ⋅ VARSEO XS Conventions These operating instructions contain references to DANGER residual hazards, important user tips and handling This reference identifies hazards, instructions that are identified with the following which will result in serious injury or symbols and signal words.
English ⋅ VARSEO XS Warranty and Liability Our "General terms and conditions of sale and The manufacturer has no knowledge of any delivery" apply. These terms and conditions are improper use up to this time. available to the operating company upon conclusion of the contract, at the latest.
English ⋅ VARSEO XS Unpacking / Packing CAUTION Damage during transport without original packaging • Please keep the original packaging materials. • Always ship the device with the orig- inal packaging. ≥ 20 kg...
WARNING approved by BEGO. Any other use is deemed to be improper. We shall not be liable for any damage Risk of injury! resulting from improper use.
Page 10
NOTE Important! Never operate the device without supervision! Using resins The VARSEO XS resin tank should only be filled WARNING with resin or cleaned with ethanol under exhaust ventilation or in a well ventilated room to be Risk of injury...
English ⋅ VARSEO XS Device description VARSEO XS - compact 3D printer with user-friendly operating and control concept In combination with tested and proven materials, the Front view: device facilitates printing a variety of 3D objects using state-of-the-art stereolithographic technology.
NOTE Deviating functions are described separately. Basic principles VARSEO XS uses a powerful LED light source to create plastic objects by means of solidifying liquid resin mixtures. To prevent premature solidifying of the resin mixture it must only be used in an area that is protected from light or darkened, respectively.
English ⋅ VARSEO XS Scope of delivery and accessories Available forms Accessories Varseo XS ............26490 Cover for Varseo XS resin tank (3x)....20625 Varseo accessories set ......... 41041 Scope of delivery • Varseo spray bottle (1x) • Varseo measuring cup (1x) Original operating instructions Varseo XS (on the •...
Elevation..........up to 2000 m Weight ............. 11 kg Print rate........... up to 30 mm/h BEGO CAMcreator Print The BEGO CAMcreator software allows you to NOTE create and process different dental objects for the If you do not have admin rights then have the VARSEO XS.
English ⋅ VARSEO XS Installation NOTE • The device should be installed in a well-venti- lated area. The distance to the wall must be at least 10 cm to ensure that there is enough space for proper device ventilation. •...
A registration is required in order to activate your Export the machine data from the device to the BEGO Varseo XS 3D printer requires. Using your provided USB flash drive (→ page 30). chosen access data, you can login to Open the "BEGO Varseo Activation.exe"...
Page 17
English ⋅ VARSEO XS Switching the VARSEO XS on Connect the device to a power supply outlet (2) with the supplied power supply unit. Switch the device on with the power switch (1). The display will light up automatically. INITIALIZING PLEASE WAIT…...
Page 18
10. Press the HOME button to call up the main menu. NOTE The Varseo XS printer must always be online to execute print jobs. The network connection can be established via LAN cable or WIFI. • Setting up a network connection via LAN cable →...
Page 19
English ⋅ VARSEO XS Setting up a network connection via LAN cable NOTE NOTE A connection without DHCP is not possible. A LAN cable is not included in the scope of Please contact your system administrator to set delivery. Use at least a CAT5e patch cable with a up DHCP in your network.
Page 20
English ⋅ VARSEO XS • The LAN MAC address will be displayed. LAN MAC: Press the HOME button to call up the main XX:XX:XX:XX:XX: menu. [OK] BACK If an error message appears, check the con- LAN IS NOT nectors of the LAN cable on the back of the CONNECTED device and on the router.
Page 21
English ⋅ VARSEO XS If no available WIFI network is found, an infor- NO NETWORK FOUND mation screen will appear. Select the following SEARCH AGAIN ► menu item for a new search CANCEL > SEARCH AGAIN To abort the search, select: >...
Page 22
English ⋅ VARSEO XS 11. Enter the password with the keypad. Four PASSWORD [ABC] entry modes are available: • English upper case letters (A-Z), [HOME] KEY MODE • English lower case letters (A-Z), [OK] TO FINISH • Arabic numerals (0-9) and •...
Page 23
[OK] BACK Press the HOME button to return to the main menu. Automatic firmware updates The VARSEO XS is updating the device software to SYSTEM UPDATE IN the latest firmware version via my.BEGO.com. Upon PROGRESS... every restart and after every print job, the device...
English ⋅ VARSEO XS Operating the build platform NOTE • Notes on cleaning the build platform → page 35 • We recommend using a separate resin tank and build platform for every indication to avoid any cross-contamination. Removing the build platform Turn the screw (1) on the build platform (2) counterclockwise all the way to the stop.
English ⋅ VARSEO XS Operating the resin tank NOTE CAUTION • Remove the resin tank for filling or replace- Property damage ment and to clean the device. Always remove the build platform • We recommend using a separate resin tank...
Page 26
English ⋅ VARSEO XS Filling the resin tank NOTE WARNING • Switch the printer on and fill the resin tank with Risk of injury the corresponding resin before sending the The resin may cause allergic print job to the printer! reactions.
English ⋅ VARSEO XS Printing objects NOTE CAUTION The VARSEO XS printer must always be online Property damage to execute print jobs. • Make sure that there are prints or • Setting up a network connection via LAN cable material residues on the build plat- →...
Page 28
→ Page 17, Section "Checking the LAN connection" or → Page 20, Section "Checking the WIFI connection") Please refer to the brief instructions for BEGO CAMcreator Print software. The print job will start automatically once the print file has been successfully transferred.
Page 29
English ⋅ VARSEO XS Stopping or aborting a print job To stop or abort a print job, select the corre- ACTIVE MENU sponding menu: PAUSE TASK > PAUSE TASK CANCEL TASK > CANCEL TASK BACK ► > BACK Confirm your entry with the OK button.
Page 30
English ⋅ VARSEO XS Detaching object from the build platform WARNING WARNING Risk of injury Risk of injury • Any resin spilt on the floor must be Ethanol is highly flammable. wiped up and cleaned using ethanol • Keep the container closed tightly.
English ⋅ VARSEO XS Special functions Pack mode Activate the "pack mode" function when packaging the printer for transport (→ Page 6, Section "Unpacking / Packing"). Clean the resin tank (→ page 35) before pack- aging the device. Place the protective material inside the resin tank.
Page 32
(→ page 14). This file can also be used to add the Varseo XS to the BEGO CAMcreator Print software. Both of these steps are necessary for the successful use of the Varseo XS.
English ⋅ VARSEO XS Printer settings Switching the buzzer on and off When the buzzer is activated (on), the printer will SETTINGS emit an acoustic signal when a button is actuated. NETWORK [LAN] The buzzer is set to on by default.
Page 34
English ⋅ VARSEO XS Saving energy The LED backlighting of the LCD display improves SETTINGS the legibility of the screen content. Backlighting is WIFI set to on by default. It can be temporarily be deacti- BUZZER vated with the energy save mode.
Page 35
Press the HOME button to return to the main menu. Open the help Call up the following menu to display the HELP address of the BEGO website and confirm MY.BEGO.COM every selection with the OK button: WWW.BEGO.COM > INFO [OK] BACK >...
English ⋅ VARSEO XS Service and Maintenance WARNING CAUTION Electrical hazards Property damage Switch the device off and disconnect it The resin is sensitive to light. from the power supply before carrying • In order to prevent the resin from...
Page 37
English ⋅ VARSEO XS Cleaning the build platform Scrape all hardened resin residues from the surface. Make sure that no hardened resin res- idues remain on the build platform. Remove any excessive resin form the surfaces of the build platform. This is of particular impor- tance if you want to use a different or new resin.
English ⋅ VARSEO XS Troubleshooting Service must only be carried out by authorized BEGO repair shops! Technical service hotline: +49 (421) 2028 - (270 … 274) Error messages Error code Cause Action 1001 - 1009 Please contact an authorized BEGO repair shop.
Page 39
Please contact an authorized BEGO repair shop. 509…511 The allotted amount inside of the Use a new BEGO resin bottle as soon as the allotted BEGO resin bottle is running low or amount has been used up. has been used up.
Disposal in Germany BEGO offers a solution for the disposal of all BEGO devices sold and put into operation in Germany after August 13, 2005. Please contact us when it is time to dispose of the device.
Page 44
Directiva, 2006/42/CE, 2011/65/UE, 2014/30/UE, 2014/53/UE. · Français Par la présente, XYZprinting Netherlands B.V., déclare que les appareils du type Varseo XS sont conformes aux exigences essentielles et aux autres dispositions pertinentes de la directive 2006/42/CE, 2011/65/UE, 2014/30/UE, 2014/53/UE. ·...