INSTALLATION
11. Put the hinge cover and the screw cover
back.
GB
NO
12. With the door closed, check that the door
is aligned horizontally and vertically and
SE
that the seal is closed on all sides before
finally tightening the bottom hinge.
FI
Re-adjust the levelling feet as needed.
DK
CZ
SK
In some cases, the door seal may be crushed after prolonged storing pressure,
resulting to the door seal not able to close properly when reversed.
Follow the steps below to solve the issue:
1. Peel off the door seal from the upper or lower corner
2. Rotate the door seal upside down so that the side
3. Insert the door seal back into the door from the
4. If the issue still occurs, contact your local service centre for assistance.
28
and warm it with a hairdryer; the warmth can allow
the door seal to return to its original form. Do not
blow directly on the unit as the warmth may damage
other parts of the unit.
originally with the hinge stay with the hinge.
upper or lower corner.
180°