Configuration Options:
The MSI-22 is designed to accommodate many applications. For most applications the factory default
setting is sufficient. For 'special' applications a few jumpers may need to be moved. These Jumpers
determine how the MSI-22 interacts with other Components of the System
Before attempting a Configuration you should review the "BUSS Systems Guide" CI & PA, BUSS
sections
The MSI-22 consists of five Functional Modules:
Two Inputs; Local Microphone/Line Input; PA-BUSS Input
Two Outputs; PA-BUSS Monitor/Communications Output; Speaker Amplifier
CI-BUSS Interface
The Jumper Options determine how these Modules interact and function with each other
The "Standard Configuration" is a Remote (Single Location) for use with an Operator Console
This is a Remote (Single Location) for use with an Operator Console, CI-ODC
The Power Amplifier, is used for a Procedure Room Ceiling Speaker
The PA-OUT, is used as Procedure Room Communications
The PA-IN, may or may not be used for another Microphone
The CI-BUSS may be used with other Interfaces, such as a CI-HSI-41
PA-BUSS IN
POWER
ON
OFF
Jumper Options
10/29/2019
Tech Works CI-Series Systems Planning & Installation Manual
PA-BUSS OUT
SOURCE
ALC_OUT
PA_INPUT
MA-INPUT
SL-INPUT
ON OFF
DUCKING
TALK CI-ALERT
NONE
LO
MED
MUTE
AUDIO
KEYED ALWAYS
KEYING
ALWAYS
CI-ALERT
TALK
PA-IN ALERT
ON
OFF
PA OFF AUDIO
PA IN
NONE
C
- I
B
U
S
S
C
- I
B
U
S
S
SOURCE-SLAVE
SOURCE-MASTER
MA-INPUT
SL-INPUT
ALC-OUT
ALC-OUT
PA-INPUT
PA-INPUT
O
N
O
F
F
O
N
O
F
F
Tech Works
CI-MSI-22
REV-2.2
PHANTOM
ON OFF
GAIN RANGE
LO
HI
MIC ON
SW ALWAYS
AMPLIFIER SOURCE
ALC_OUT
PA_INPUT
MA-INPUT
SL-INPUT
ON
OFF
AUDIO ON
ALWAYS
DUCKING
CI-ALERT
TALK CI-ALERT
NONE
ON OFF
LO
MED
MUTE
Page 27 of 42