20 December 1996
-Reinstallation-
A219R509.wmf
1. Reinstall the 1st scanner. (2 screws [A]; do not fully tighten the screws.)
2. Remove the lens cover [B].
NOTE: When replacing the lens cover, be sure to:
Position the ribbon cable [C] so that it is not caught by the
cover, as shown.
Insert the tabs [D] into the slots [E].
Position the harness [F] alongside the cover, as shown.
Position the cover pin [G] and tab [H] as shown.
3. Slide the 1st scanner fully to the right. Line up and insert the two scanner
locking pins [I].
NOTE: Scanner positioning pins are available as a service part.
P/N: A184 9501 (See the Parts Catalog.)
4. Connect the two connectors and secure the harness to the clamps.
5. Tighten the two screws [A] to secure the 1st scanner.
6. Remove the scanner positioning pins [I].
7. Install the lens cover, the exposure glass and exterior covers.
8. Check the image quality. Perform the Focus Adjustment (see Focus
Adjustment) and the Horizontal Magnification Adjustment (see Horizontal
Magnification Adjustment), if necessary.