Water Right Impression Plus Series Installation Instructions & Owner's Manual

Water Right Impression Plus Series Installation Instructions & Owner's Manual

Twin water softeners

Advertisement

Impression Plus Series
Sanitizer Plus Series
Twin Water Softeners
®
®
For Models:
• IMP-844TW
• ASP1-1044TW
• IMP-1044TW
• ASP1-1054TW
• IMP-1054TW
• ASP1-1354TW
• IMP-1354TW
• ASP1-1465TW
• IMP-1465TW
• ASP1-1665TW
• IMP-1665TW
• IMPRC-1054TW
• ASP2-1044TW
• IMPRC-1354TW
• ASP2-1054TW
• ASP2-1354TW
• ASP2-1465TW
• ASP2-1665TW

Advertisement

Table of Contents
loading

Summary of Contents for Water Right Impression Plus Series

  • Page 1 Impression Plus Series ® Sanitizer Plus Series ® Twin Water Softeners For Models: • IMP-844TW • ASP1-1044TW • IMP-1044TW • ASP1-1054TW • IMP-1054TW • ASP1-1354TW • IMP-1354TW • ASP1-1465TW • IMP-1465TW • ASP1-1665TW • IMP-1665TW • IMPRC-1054TW • ASP2-1044TW • IMPRC-1354TW •...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Pre-Installation Instructions for Dealers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Bypass Valve .
  • Page 3: Pre-Installation Instructions For Dealers

    PRE-INSTALLATION INSTRUCTIONS FOR DEALERS The manufacturer has preset the water treatment unit’s sequence of cycles, cycle times, salt dose, exchange capacity and salt dose refill time . The dealer should read this page and guide the installer regarding hardness, day override, time of regeneration, service alarm and buzzer alarm settings before installation.
  • Page 4: Bypass Valve

    BYPASS VALVE The bypass valve is typically used to isolate the control valve from the plumbing system’s water pressure in order to perform control valve repairs or maintenance . The 1” full flow bypass valve incorporates four positions, including a diagnostic position that allows a service technician to have pressure to test a system while providing untreated bypass water to the building .
  • Page 5: Installation

    INSTALLATION GENERAL INSTALLATION & SERVICE WARNINGS The control valve, fittings and/or bypass are designed to accommodate minor plumbing misalignments . There is a small amount of “give” to properly connect the piping, but the water softener is not designed to support the weight of the plumbing . Do not use Vaseline, oils, other hydrocarbon lubricants or spray silicone anywhere .
  • Page 6 INSTALLATION Ring . Solder joints should be cool and solvent cements should be set before installing the nut, split ring and “O” Ring . Avoid getting solder flux, primer, and solvent cement on any part of the “O” Rings, split rings, bypass valve or control valve .
  • Page 7 INSTALLATION 9 . SAFETY BRINE TANK CONNECTION: Install the 3/8” O .D . polyethylene tube from the Refill Elbow to the Brine Safety Float valve in the brine tank . Connection at Refi ll Elbow on the control valve Connection at Brine Safety Float in brine tank 10 .
  • Page 8: Programming Procedures

    PROGRAMMING PROCEDURES 1. Set time of day: Time of day should only need to be set after extended power outages or when daylight saving time begins or ends . If an extended power outage occurs, the time of day will flash on and off indicating that the time should be reset . STEP 1 –...
  • Page 9 PROGRAMMING PROCEDURES STEP 4 – IMMEDIATE REGENERATION: The manufacturer has set the REGEN IMMEDIATE regeneration to occur when zero gallons remain . When this occurs, ON ZERO the standby tank will switch into service and provide treated water while the tank requiring regeneration will start this process . STEP 5 –...
  • Page 10: Start-Up Instructions

    START-UP INSTRUCTIONS FLUSHING OF SYSTEM: To flush the system of any debris and air after installation is complete, please perform the following steps: 1 . Rotate bypass handles to the bypass mode (Fig. 2 on page 4) . 2 . Turn on inlet water and check for leaks in the newly installed plumbing . 3 .
  • Page 11: Operating Displays And Maintenance

    OPERATING DISPLAYS AND MAINTENANCE 1 . GENERAL OPERATION: When the system is operating, one of five displays may be shown and will alternate with the installing dealer’s name and phone number (if set) for future service . Pressing will alternate between the displays . NEXT 1 .
  • Page 12 OPERATING DISPLAYS AND MAINTENANCE 4 . POWER LOSS AND BATTERY REPLACEMENT: If an extended power outage BATTERY REPLACEMENT occurs, the control valve will retain the time of day settings until the board’s battery is depleted . Once the battery is depleted, the display will appear dark and absent of any information .
  • Page 13: Troubleshooting Guide

    TROUBLESHOOTING GUIDE PROBLEM CAUSE CORRECTION A . No power at electric outlet A . Repair outlet or use working outlet B . Control valve power adapter not plugged into B . Plug power adapter into outlet or connect outlet or power cord end not connected to PC power cord end to PC board connection board connection 1.
  • Page 14 TROUBLESHOOTING GUIDE PROBLEM CAUSE CORRECTION A . Turn bypass handles to place bypass in A . Bypass valve in bypass position service position 7. Control valve does not B . Meter is not connected to meter connection on B . Connect meter to three pin connection labeled regenerate automatically PC board METER on PC board...
  • Page 15 TROUBLESHOOTING GUIDE PROBLEM CAUSE CORRECTION A . Injector is plugged A . Remove injector and clean or replace B . Faulty regenerant piston B . Replace regenerant piston C . Regenerant line connection leak C . Inspect regenerant line for air leak 12.
  • Page 16 TROUBLESHOOTING GUIDE PROBLEM CAUSE CORRECTION A . Check motor connections then Press NEXT and REGEN buttons for 3 seconds to resynchronize A . Motor failure during a regeneration software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect .
  • Page 17 TROUBLESHOOTING GUIDE PROBLEM CAUSE CORRECTION 20. Err – 109 A . Invalid motor state detected A . Replace PC board 21. Err – 201 A . Invalid regeneration cycle step detected A . Replace PC board A . Check for low flow leak . Press NEXT and A .
  • Page 18: Service Instructions For Transfer Assemblies

    SERVICE INSTRUCTIONS TRANSFER CAP ASSEMBLIES SERVICE INSTRUCTIONS Release locking tabs 1 . The backplate of the control valve must from each side to first be removed to allow access to the remove back plate. transfer cap assembly . 2 . Hold slight downward pressure on the top left corner of the backplate while using a thin flat screwdriver or knife blade to push in on the locking tabs .
  • Page 19 SERVICE INSTRUCTIONS 13 . Prior to reinstalling the discs, the drive shaft should be removed and the O-rings cleaned, inspected and lubricated with Dow #7 silicone grease . The shaft can now be installed into the disc prior to installation . 14 .
  • Page 20: Replacement Parts

    REPLACEMENT PARTS FRONT COVER AND DRIVE ASSEMBLY Item No. Part No. Description Qty. CV3540P-A Impression Plus black cover ® CV3540P-W-A Impression Plus gray cover ® CV3540S-A Sanitizer Plus black cover ® CV3540S-W-A Sanitizer Plus gray cover ® CV3107-1 Motor CV3002A Drive bracket &...
  • Page 21 REPLACEMENT PARTS PISTON ASSEMBLY Item No. Part No. Description Qty. CV3005 1” spacer stack assembly CV3004 Drive cap assembly CV3135 O-ring 228 CV3011 1” piston assembly downflow CV3011-01 1” piston assembly upflow CV3174 Regenerant piston CV3541 Drive backplate IN/OUT HEAD (FOR TANK B) Item No.
  • Page 22 REPLACEMENT PARTS...
  • Page 23 REPLACEMENT PARTS TWIN TRANSFER Item No. Part No. Description Qty. CV3470 Screw, BHC 1/4-20 x 1 SS CV3724 Washer, flat SS 1/4 CV4005-01 T1 transfer cap assembly CV4029 O-ring 236 CV4015 T1 transfer spring CV4014 T1 transfer spring support CV4036 T1 rotor disk assembly CV3105 O-ring 215 (distributor tube)
  • Page 24 REPLACEMENT PARTS BYPASS VALVE Item No. Part No. Description Qty. CV3006 Bypass assembly CV3147 Bypass handles BRINE ELBOW ASSEMBLY Item No. Part No. Description Qty. CV3195-01 Refill port plug assembly CH4615 Elbow locking clip Loosens Injector And CV4144 3/8” Elbow, Parker fitting Bypass Caps CV3163 O-ring 019...
  • Page 25 REPLACEMENT PARTS INJECTOR ASSEMBLIES Item No. Part No. Description Qty. CV3176 Injector cap CV3152 O-ring 135 CV3177-01 Injector screen CV3010-1Z Injector assembly plug CV3010-1A A injector assembly, BLACK CV3010-1B B injector assembly, BROWN C injector assembly, CV3010-1C VIOLET CV3010-1D D injector assembly, E injector assembly, CV3010-1E WHITE...
  • Page 26 REPLACEMENT PARTS DRAIN LINE ASSEMBLY 3/4” DRAIN LINE ASSEMBLY 1” Item No. Part No. Description Qty. Item No. Part No. Description Qty. CH4615 Elbow locking clip CH4615 Elbow locking clip CPKP10TS8-BULK Optional insert, 5/8” tube CV3166 Drain FTG body 1 CV3192 Optional nut, 3/4”...
  • Page 27 REPLACEMENT PARTS BRINE TANK ASSEMBLY Item No. Part No. Description Qty. CG2191- 84 Brine tank cover, injection molded WR CG2180 Brine tank cover, standard CH1095-01 Optional 18” diameter salt grid CH1080 Optional 24” diameter salt grid CG21833CB1C00 18” x 33” brine tank, black CG21840CB1C00 18”...
  • Page 28: Installation Fitting Assemblies

    INSTALLATION FITTING ASSEMBLIES Fitting Installation Instructions • Installation fittings are designed to accommodate minor plumbing misalignments, but are not designed to support the weight of a system or the plumbing . • Slide nut on first, then the split ring and O-ring . •...
  • Page 29 INSTALLATION FITTING ASSEMBLIES NOTE: Not all available fi ttings are displayed below. Contact manufacturer for optional fi ttings. 1” PVC MALE NPT ELBOW 3/4” & 1” PVC SOLVENT ELBOW Item Item Part No. Description Qty. Part No. Description Qty. CV3007 1”...
  • Page 30 INSTALLATION FITTING ASSEMBLIES NOTE: Not all available fi ttings are displayed below. Contact manufacturer for optional fi ttings. 1-1/4” & 1-1/2” BRASS SWEAT 1-1/4” & 1-1/2” PVC SOLVENT Item Item Part No. Description Qty. Part No. Description Qty. CV3007- 09 1-1/4 &...
  • Page 31 This page left intentionally blank.
  • Page 32 Twin Series Conditioners Specifications SANITIZER PLUS TWIN SPECIFICATIONS ® ASP1 SPECIFICATIONS MODEL ASP1-1044TW ASP1-1054TW ASP1-1354TW ASP1-1465TW ASP1-1665TW Minimum 7,300 @ 3.2 16,400 @ 6.1 28,300 @ 9.5 40,000 @ 13.0 51,000@ 17.0 Capacity:* (Grains/Lbs. NaCl) Medium 11,400 @ 9.3 20,700 @ 12.4 33,600 @ 15.9 47,000 @ 22.0 60,000 @ 29.0...
  • Page 33: Specifications

    Specifications IMPRESSION PLUS TWIN SPECIFICATIONS ® IMP-TW Specifications MODEL IMP-844TW IMP-1044TW IMP-1054TW IMP-1354TW IMP-1465TW IMP-1665TW Minimum 15,600 @ 3.0 23,600 @ 6.0 35,400 @ 9.0 53,000 @ 12.0 60,000 @ 18.0 80,000 @ 24.0 Capacity:* (Grains/Lbs. NaCl) Medium 21,600 @ 6.0 28,400 @ 9.0 44,400 @ 15.0 64,200 @ 18.0...
  • Page 34: Warranty

    Water Softener Limited Warranty Congratulations. You have purchased one of the fi nest water treatment systems available. In the unlikely event of a problem due to defects in material and workmanship, we proudly warrant our water softeners to the original owner, when installed in accordance with Water-Right specifi...
  • Page 35: Quick Reference Guide

    QUICK REFERENCE GUIDE BYPASS VALVE OPERATION GENERAL OPERATION To shut off water to the system, position arrow handles as shown in the bypass When the system is operating, one of five displays will be shown: operation diagram below . If your valve doesn’t look like the diagram below, 1 .
  • Page 36 1900 Prospect Court • Appleton, WI 54914 Phone: 920-739-9401 • Fax: 920-739-9406 © 2018 Water-Right All rights reserved. MAN-WR TWIN RevA0818...