Water Right Sanitizer Plus Series Installation Instructions & Owner's Manual

Water Right Sanitizer Plus Series Installation Instructions & Owner's Manual

Water conditioners

Advertisement

Sanitizer Plus Series
®
Water Conditioners

Advertisement

Table of Contents
loading

Summary of Contents for Water Right Sanitizer Plus Series

  • Page 1 Sanitizer Plus Series ® Water Conditioners...
  • Page 2: Table Of Contents

    Please study this manual carefully and understand the cautions and notes before installing. This manual should be kept for future reference. If you have any questions regarding your water conditioner, contact your local dealer or Water-Right at the following: Water-Right, Inc.
  • Page 3: Preinstallation Instructions For Dealers

    PREINSTALLATION INSTRUCTIONS FOR DEALERS: The manufacturer has preset the water treatment unit’s sequence of cycles, cycle times, salt dose, exchange capacity and salt dose refill time. The dealer should read this page and guide the installer regarding hardness, day override, and time of regeneration, before installation: For the installer, the following must be used: •...
  • Page 4 1. NORMAL OPERATION POSITION: The inlet and outlet handles point in the direction of flow indicated by the engraved arrows on the control valve. Water flows through the control valve for normal operation of a water softener. During the regeneration cycle this position provides regeneration water to the unit, while also providing untreated water to the distribution system (Fig.
  • Page 5: Installation

    INSTALLATION: GENERAL INSTALLATION & SERVICE WARNINGS The control valve, fittings and/or bypass are designed to accommodate minor plumbing misalignments. There is a small amount of “give” to properly connect the piping, but the water softener is not designed to support the weight of the plumbing. Do not use Vaseline, oils, other hydrocarbon lubricants or spray silicone anywhere.
  • Page 6: Installation

    6. INLET/OUTLET PLUMBING: Be sure to install Bypass Valve onto main control valve before beginning plumbing. Make provisions to bypass outside hydrant and cold hard water lines at this time. Install an inlet shutoff valve and plumb to the unit’s bypass valve inlet located at the right rear as you face the unit.
  • Page 7: Programming Procedures

    PROGRAMMING PROCEDURES: 1. Set time of day: Time of day should only need to be set after extended power outages or when daylight saving time begins or ends. If an extended power outage occurs, the time of day will flash on and off indicating that the time should be reset.
  • Page 8: Operating Displays And Instructions

    WATER HARDNESS DAYS BETWEEN REGEN STEP 4 – REGENERATION HOUR: The manufacturer has factory set 2:00 A.M. as the default. This is the hour of day for regeneration and can be reset by using + or — buttons. “AM/PM” toggles after 12. The default time is 2:00 a.m. (recommended for a normal household). Press to go to step 5.
  • Page 9 DAYS TO A REGEN FLOW RATE If the system has called for a regeneration that will occur at the preset time of regeneration, the words “REGEN TODAY” will appear on the display. If a water meter is installed, “GPM” flashes on the display when water is being treated, indicating gallons per minute going through the system.
  • Page 10 4. POWER LOSS AND BATTERY REPLACEMENT: The AC transformer comes with a 15 foot power cord and is BATTERY REPLACEMENT designed for use with the control valve; the transformer should only be used in a dry location. In the event of a power outage, the control valve will remember all settings and time of day.
  • Page 11: Start-Up Instructions

    START-UP INSTRUCTIONS: • After installation is complete, rotate bypass handles to bypass mode (see Fig.2 on page 4). • Turn on water and check for leaks. • Fully open a cold water faucet — preferably a laundry sink or bathtub without an aerator. •...
  • Page 12: Troubleshooting Guide

    TROUBLESHOOTING GUIDE: PROBLEM CAUSE CORRECTION A. transformer unplugged A. reconnect transformer Timer does B. no power at outlet B. repair or use working outlet not display C. defective transformer C. replace transformer time of day D. defective PC board D. replace PC board Timer does not A.
  • Page 13 PROBLEM CAUSE CORRECTION A. motor not operating A. replace motors B. no power at outlet B. repair outlet or use working outlet C. defective transformer C. replace transformer Valve stalled in D. defective PC board D. replace PC board regeneration E.
  • Page 14: Replacement Parts

    REPLACEMENT PARTS: FRONT COVER AND DRIVE ASSEMBLY Item No. Part No. Description Qty. CV3540S-A Black cover CV3540-WS-A Gray cover CV3107-1 Motor CV3106-1 Drive bracket & spring clip CV3554WS PC board, CC CV3110 Drive gear, 12 x 36 CV3109 Drive gear cover CV3002CC Drive assembly, CC CV3526...
  • Page 15 REPLACEMENT PARTS: PISTON ASSEMBLY Item No. Part No. Description Qty. CV3005 1" spacer stack assembly CV3430 1.25" spacer stack assembly CV3004 Drive cap assembly CV3135 O-ring 228 CV3011 1" piston assembly downflow CV3011-01 1" piston assembly upflow CV3407 1.25" piston assembly downflow CV3174 Regenerant piston CV3180...
  • Page 16 REPLACEMENT PARTS: BYPASS VALVE Item No. Part No. Description Qty. CV3151 Nut, 1" quick connect CV3150 Split ring CV3105 O-ring 215 CV3145 Bypass rotor, 1" CV3146 Bypass cap CV3147 Bypass handle CV3148 Bypass rotor seal retainer CV3152 O-ring 135 CV3155 O-ring 112 CV3156 O-ring 214...
  • Page 17 REPLACEMENT PARTS: INJECTOR ASSEMBLIES Item No. Part No. Description Qty. CV3176 Injector cap CV3152 O-ring 135 CV3177 Injector screen CV3010-1Z Injector assembly plug CV3010-1A A injector assembly, BLACK CV3010-1B B injector assembly, BROWN CV3010-1C C injector assembly, VIOLET D injector assembly, CV3010-1D CV3010-1E E injector assembly,...
  • Page 18 REPLACEMENT PARTS: DRAIN LINE ASSEMBLY 3/4" Item No. Part No. Description Qty. CH4615 Elbow locking clip CPKP10TS8-BULK Optional insert, 5/8" tube CV3192 Optional nut, 3/4" drain elbow CV3158-01 Drain elbow, 3/4" NPT with O-ring CV3163 O-ring 019 CV3159-01 DLFC retainer assembly CV3162-007 0.7 DLFC for 3/4"...
  • Page 19 REPLACEMENT PARTS: WATER METER & METER PLUG Item No. Part No. Description Qty. CV3151 Nut, 1" QC CV3003 Meter assembly, includes items 3 & 4 CV3118-01 Turbine assembly CV3105 O-ring 215 CV3003-01 Meter plug assembly CV3013 Optional mixing valve...
  • Page 20 REPLACEMENT PARTS: BRINE TANK ASSEMBLY Item No. Part No. Description Qty. CG2191-49 Brine tank cover, injection molded WR CG2180 Brine tank cover, standard CH1072-01 Optional 18" diameter salt grid CH1080 Optional 24" diameter salt grid CG21833CB1C00 18" x 33" brine tank, black CG21840CB1C00 18"...
  • Page 21 INSTALLATION FITTING ASSEMBLIES: 1" PVC MALE NPT ELBOW 3/4" & 1" PVC SOLVENT ELBOW Item Item Part No. Description Qty. Part No. Description Qty. CV3007 1" PVC male NPT elbow assembly CV3007- 01 3/4" & 1" PVC solvent elbow assembly CV3151 Nut, 1"...
  • Page 22 1-1/4" & 1-1/2" BRASS SWEAT 1-1/4" & 1-1/2" PVC SOLVENT Item Item Part No. Description Qty. Part No. Description Qty. CV3007- 09 1-1/4 & 1-1/2" brass sweat assembly CV3007- 07 1-1/4" & 1-1/2" PVC solvent assembly CV3151 Nut, 1" quick connect CV3151 Nut, 1"...
  • Page 23: Specifications

    SPECIFICATIONS: MODEL ASP1-1044 ASP1-1054 ASP1-1354 ASP2-1044 ASP2-1054 ASP2-1354 Capacity: Maximum 11,800 @ 12.4 22,600 @ 15.9 36,900 @ 21.2 20,300 @ 12.4 34,800@ 15.9 60,300 @ 26.5 (Grains/Lbs. NaCI) Medium 11,400 @ 9.3 20,700 @ 12.4 33,600 @ 15.9 19,100 @ 9.3 32,000 @ 12.4 48,300 @ 15.9 Minimum...
  • Page 24: Quick Reference Guide

    QUICK REFERENCE GUIDE: GENERAL OPERATION MANUAL REGENERATION When the system is operating, one of four displays will be shown: NOTE: For softeners, if brine tank does REGEN TODAY and TIME OF DAY time of day/gpm, flow rate, capacity remaining or days to a regen. not contain salt, fill with salt and wait at will flash alternately if a regeneration Pressing...