Please study this manual carefully and understand the cautions and notes before installing. This manual should be kept for future reference. If you have any questions regarding your water conditioner, contact your local dealer or Water-Right at the following: Water-Right, Inc.
PREINSTALLATION INSTRUCTIONS FOR DEALERS: The manufacturer has preset the water treatment unit’s sequence of cycles, cycle times, salt dose, exchange capacity and salt dose refill time. The dealer should read this page and guide the installer regarding hardness, day override, and time of regeneration, before installation: For the installer, the following must be used: •...
Page 4
1. NORMAL OPERATION POSITION: The inlet and outlet handles point in the direction of flow indicated by the engraved arrows on the control valve. Water flows through the control valve for normal operation of a water softener. During the regeneration cycle this position provides regeneration water to the unit, while also providing untreated water to the distribution system (Fig.
INSTALLATION: GENERAL INSTALLATION & SERVICE WARNINGS The control valve, fittings and/or bypass are designed to accommodate minor plumbing misalignments. There is a small amount of “give” to properly connect the piping, but the water softener is not designed to support the weight of the plumbing. Do not use Vaseline, oils, other hydrocarbon lubricants or spray silicone anywhere.
6. INLET/OUTLET PLUMBING: Be sure to install Bypass Valve onto main control valve before beginning plumbing. Make provisions to bypass outside hydrant and cold hard water lines at this time. Install an inlet shutoff valve and plumb to the unit’s bypass valve inlet located at the right rear as you face the unit.
PROGRAMMING PROCEDURES: 1. Set time of day: Time of day should only need to be set after extended power outages or when daylight saving time begins or ends. If an extended power outage occurs, the time of day will flash on and off indicating that the time should be reset.
WATER HARDNESS DAYS BETWEEN REGEN STEP 4 – REGENERATION HOUR: The manufacturer has factory set 2:00 A.M. as the default. This is the hour of day for regeneration and can be reset by using + or — buttons. “AM/PM” toggles after 12. The default time is 2:00 a.m. (recommended for a normal household). Press to go to step 5.
Page 9
DAYS TO A REGEN FLOW RATE If the system has called for a regeneration that will occur at the preset time of regeneration, the words “REGEN TODAY” will appear on the display. If a water meter is installed, “GPM” flashes on the display when water is being treated, indicating gallons per minute going through the system.
Page 10
4. POWER LOSS AND BATTERY REPLACEMENT: The AC transformer comes with a 15 foot power cord and is BATTERY REPLACEMENT designed for use with the control valve; the transformer should only be used in a dry location. In the event of a power outage, the control valve will remember all settings and time of day.
START-UP INSTRUCTIONS: • After installation is complete, rotate bypass handles to bypass mode (see Fig.2 on page 4). • Turn on water and check for leaks. • Fully open a cold water faucet — preferably a laundry sink or bathtub without an aerator. •...
TROUBLESHOOTING GUIDE: PROBLEM CAUSE CORRECTION A. transformer unplugged A. reconnect transformer Timer does B. no power at outlet B. repair or use working outlet not display C. defective transformer C. replace transformer time of day D. defective PC board D. replace PC board Timer does not A.
Page 13
PROBLEM CAUSE CORRECTION A. motor not operating A. replace motors B. no power at outlet B. repair outlet or use working outlet C. defective transformer C. replace transformer Valve stalled in D. defective PC board D. replace PC board regeneration E.
REPLACEMENT PARTS: FRONT COVER AND DRIVE ASSEMBLY Item No. Part No. Description Qty. CV3540S-A Black cover CV3540-WS-A Gray cover CV3107-1 Motor CV3106-1 Drive bracket & spring clip CV3554WS PC board, CC CV3110 Drive gear, 12 x 36 CV3109 Drive gear cover CV3002CC Drive assembly, CC CV3526...
QUICK REFERENCE GUIDE: GENERAL OPERATION MANUAL REGENERATION When the system is operating, one of four displays will be shown: NOTE: For softeners, if brine tank does REGEN TODAY and TIME OF DAY time of day/gpm, flow rate, capacity remaining or days to a regen. not contain salt, fill with salt and wait at will flash alternately if a regeneration Pressing...