Water Right Impression Master Programming Manual

Water Right Impression Master Programming Manual

Hide thumbs Also See for Impression:

Advertisement

Quick Links

Master Programming Manual
for Impression, Impression Plus,
and Impression Twin Models
Effective January 2018

Advertisement

loading

Summary of Contents for Water Right Impression

  • Page 1 Master Programming Manual for Impression, Impression Plus, and Impression Twin Models Effective January 2018...
  • Page 2 Button appearance and position may be different than actual valve Cycle times, sequences, and settings in this guide are only examples of how your system may be programmed. Actual settings are determined by the manufacturer. Please contact them if more information is needed. Important button sequences to note: 1.
  • Page 3 Softener Installer/User Screens Accessed by pressing and holding NEXT and + simultaneously for three seconds. Returns to general display after five minutes of inactivity. Set water hardness with + or — buttons. WATER HARDNESS Adjustable from 1-150 grains, within limits determined by capacity settings as to not override gallons capacity setting.
  • Page 4 Filter Installer/User Screens Accessed by pressing and holding NEXT and + simultaneously for three seconds. Returns to general display after five minutes of inactivity. Set days between a regeneration with + or — buttons. DAYS BETWEEN REGEN Adjustable from 1-28 days, or OFF. Default setting is 3.
  • Page 5 Service/OEM SOFTENING Screens Accessed by pressing and holding NEXT and simultaneously for three seconds. — Returns to general display after five minutes of inactivity. Select SOFTENING or FILTERING with + or — buttons. SOFTENING TYPE If you have selected FILTERING, please refer to “Service/OEM FILTERING screens”, page 7-8.
  • Page 6 Service/OEM SOFTENING Screens cont’d Accessed by pressing and holding NEXT and simultaneously for three seconds. — Returns to general display after five minutes of inactivity. continued from previous page Set fourth cycle position with + or — buttons. REGENERANT DRAW DN CYCLE 4 Set draw time with + or —...
  • Page 7 Service/OEM FILTERING Screens Accessed by pressing and holding NEXT and simultaneously for three seconds. — Returns to general display after five minutes of inactivity. NOTE: Numbers and cycles used as examples on this page are typical of AIR FILTER systems. Select SOFTENING or FILTERING with + or —...
  • Page 8 Service/OEM FILTERING Screens cont’d Accessed by pressing and holding NEXT and simultaneously for three seconds. — Returns to general display after five minutes of inactivity. NOTE: Numbers and cycles used as examples on this page are typical of AIR FILTER systems. continued from previous page DRAW TIME Set draw time with + or —...
  • Page 9: Configuration Screens

    Configuration Screens Accessed by pressing and holding NEXT and simultaneously for three seconds. — Once screen changes, press and hold NEXT and simultaneously again for three seconds. — Select meter size with + or — buttons. VALVE TYPE Set to 1”, 1.25”, 1.5”, 2” or 1.0T (for twin units). Upflow brining will not be an option if set to anything other than 1” or 1.0T. With 1.0T set: •...
  • Page 10 Configuration Screens cont’d Accessed by pressing and holding NEXT and simultaneously for three seconds. — Once screen changes, press and hold NEXT and simultaneously again for three seconds. — continued from previous page Set first relay trigger with + button. Press + to reach desired triggering event. RELAY 1 TRIGGER If not using a relay, make sure OFF is selected and press NEXT.
  • Page 11 Configuration Screens cont’d Accessed by pressing and holding NEXT and simultaneously for three seconds. — Once screen changes, press and hold NEXT and simultaneously again for three seconds. — continued from previous page Set relay trigger with + or — buttons. RELAY 1 TRIGGER REGEN REGEN GALLONS indicates that relay will be energized after a specified number of...
  • Page 12 First Level History Screens Accessed by pressing and holding + and — simultaneously for three seconds. Returns to general display after five minutes of inactivity. DAYS SINCE REGEN Displays number of days since last regen. VOLUME SINCE REGEN Displays number of gallons since last regen. RESERVE FOR Displays reserve capacity.
  • Page 13 First Level History Screens cont’d Accessed by pressing and holding + and — simultaneously for three seconds. Returns to general display after five minutes of inactivity. continued from previous page Displays peak flow rate history. MAX FLOW HISTORY Use + or — buttons to scroll through last 7 days to view peak flow rate for that day.
  • Page 14: Error Codes And Descriptions

    Second Level History Screens Accessed by pressing + and — simultaneously for three seconds. Once screen changes, press + and — simultaneously again for three seconds. Non-resettable history. Displays total regens since startup. Displays software version. SOFTWARE VERSION TOTAL REGENS Displays total gallons used Displays last ten valve errors that occurred.
  • Page 15 Notes...