Water Right Impression Series Installation Instructions & Owner's Manual

Water Right Impression Series Installation Instructions & Owner's Manual

For models: ims-1054, imbf-1044, ims-1248, imbf-1054, ims-1354, imbf-1354, imfe-1054, imbf-1044man, imfe-1248, imbf-1054man, imfe-1354, imbf-1354man, iag-1054, iman-1044, iag-1248, iman-1054, iag-1354, iman-1354, iacg-1054an, iacg-1248an, iacg-1354an

Advertisement

Impression Series
Impression Plus Series
Water Filters
®
®
For Models:
• IMS-1054
• IMBF-1044
• IMS-1248
• IMBF-1054
• IMS-1354
• IMBF-1354
• IMFE-1054
• IMBF-1044MAN
• IMFE-1248
• IMBF-1054MAN
• IMFE-1354
• IMBF-1354MAN
• IAG-1054
• IMAN-1044
• IAG-1248
• IMAN-1054
• IAG-1354
• IMAN-1354
• IACG-1054AN
• IACG-1248AN
• IACG-1354AN

Advertisement

Table of Contents
loading

Summary of Contents for Water Right Impression Series

  • Page 1 Impression Series ® Impression Plus Series ® Water Filters For Models: • IMS-1054 • IMBF-1044 • IMS-1248 • IMBF-1054 • IMS-1354 • IMBF-1354 • IMFE-1054 • IMBF-1044MAN • IMFE-1248 • IMBF-1054MAN • IMFE-1354 • IMBF-1354MAN • IAG-1054 • IMAN-1044 • IAG-1248 •...
  • Page 2: Table Of Contents

    . Your Impression Series water filters are precision built, high quality products . These units will deliver filtered water for many years to come, when installed and operated properly . Please study this manual carefully and understand the cautions and notes before installing .
  • Page 3: Pre-Installation Instructions For Dealers

    PRE-INSTALLATION INSTRUCTIONS FOR DEALERS The manufacturer has preset the water treatment unit’s sequence of cycles and cycle times. The dealer should read this page and guide the installer regarding hardness, day override, and time of regeneration, before installation. For the installer, the following must be used: •...
  • Page 4: Bypass Valve

    BYPASS VALVE The bypass valve is typically used to isolate the control valve from the plumbing system’s water pressure in order to perform control valve repairs or maintenance. The 1” full flow bypass valve incorporates four positions, including a diagnostic position that allows a service technician to have pressure to test a system while providing untreated bypass water to the building.
  • Page 5 INSTALLATION GENERAL INSTALLATION & SERVICE WARNINGS The control valve, fittings and/or bypass are designed to accommodate minor plumbing misalignments. There is a small amount of “give” to properly connect the piping, but the water softener is not designed to support the weight of the plumbing. Do not use Vaseline, oils, other hydrocarbon lubricants or spray silicone anywhere.
  • Page 6 INSTALLATION When installing an air regenerating filter the customer may experience, under certain conditions, small amounts of air (cloudy water) at the taps. This is normal. On rare occasions, this may result in “shots of air” at a particular fixture. By installing a loop or “U” on the outlet side of the unit, this will act as an air trap and improve this situation.
  • Page 7: Installation

    INSTALLATION AIR DRAW 8. CHECK VALVE (AIR FILTRATION SYSTEMS ONLY): All air systems Screen Elbow CHECK VALVE include an internal check valve and screen assembly as part of the air draw ASSEMBLY system (see diagram at right). This check valve, screen, and elbow are Air fl...
  • Page 8: Programming Procedures

    PROGRAMMING PROCEDURES 1. Set time of day: Time of day should only need to be set after extended power outages or when daylight saving time begins or ends. If an extended power outage occurs, the time of day will flash on and off indicating that the time should be reset. STEP 1 –...
  • Page 9: Startup Instructions

    STARTUP INSTRUCTIONS FLUSHING OF SYSTEM: To flush the system of any debris and air after installation is complete, please perform the following steps: 1. Rotate bypass handles to the bypass mode (see Fig. 2 of page 4). 2. Turn on inlet water and check for leaks in the newly installed plumbing. 3.
  • Page 10: Operating Displays And Maintenance

    OPERATING DISPLAYS AND MAINTENANCE The air sulfur and air iron filter systems look and function much like any backwashing whole house filter; however, unlike these conventional filters, they use air as a regenerant. This atmospheric air (containing oxygen) helps convert iron or hydrogen sulfide into particles.
  • Page 11 OPERATING DISPLAYS AND MAINTENANCE OPERATING DISPLAYS AND MAINTENANCE Once a manual regeneration is initiated, the unit will enter the first regeneration cycle. Once the unit advances to its first position and subsequent positions thereafter, (see Start Up Instructions on page 9 for regeneration sequence) the water filter will deliver water, but it will be untreated.
  • Page 12: Replacement Mineral Instructions For Acid Neutralizers

    REPLACEMENT MINERAL INSTRUCTIONS FOR ACID NEUTRALIZERS Acid Neutralizers raise the pH of mildly acidic water. The raising of pH utilizes a sacrificial mineral that will need replenishment every 6 to 12 months. Typically the media should not be below the halfway point in the tank. In order to check the mineral height and before adding mineral to the system, please follow these instructions.
  • Page 13 REPLACEMENT MINERAL INSTRUCTIONS FOR ACID NEUTRALIZERS For Acid Neutralizers With the CD1400 In/Out Head Without an Optional Fill Plug 1. Check the media height by shining a flashlight through the tank to see the height of the mineral. If the level is not visible, and to fill the tank, the CD1400 In/Out head will need to be removed.
  • Page 14: Troubleshooting Guide

    TROUBLESHOOTING GUIDE PROBLEM CAUSE CORRECTION A. No power at electric outlet A. Repair outlet or use working outlet B. Control valve power adapter not plugged into B. Plug power adapter into outlet or connect outlet or power cord end not connected to PC power cord end to PC board connection board connection 1.
  • Page 15 TROUBLESHOOTING GUIDE PROBLEM CAUSE CORRECTION A. Turn bypass handles to place bypass in A. Bypass valve in bypass position service position 7. Control valve does not B. Meter is not connected to meter connection on B. Connect meter to three pin connection labeled regenerate automatically PC board METER on PC board...
  • Page 16 TROUBLESHOOTING GUIDE PROBLEM CAUSE CORRECTION A. Injector is plugged A. Remove injector and clean or replace B. Faulty regenerant piston B. Replace regenerant piston C. Regenerant line connection leak C. Inspect regenerant line for air leak 12. Control valve fails to D.
  • Page 17 TROUBLESHOOTING GUIDE PROBLEM CAUSE CORRECTION A. Check motor connections then Press NEXT and REGEN buttons for 3 seconds to resynchronize A. Motor failure during a regeneration software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect.
  • Page 18 TROUBLESHOOTING GUIDE PROBLEM CAUSE CORRECTION 20. Err – 109 A. Invalid motor state detected A. Replace PC board 21. Err – 201 A. Invalid regeneration cycle step detected A. Replace PC board A. Check for low flow leak. Press NEXT and A.
  • Page 19: Replacement Parts

    REPLACEMENT PARTS FRONT COVER AND DRIVE ASSEMBLY Item No. Part No. Description Qty. CV3540-A Black Impression cover ® CV3540-W-A Gray Impression cover ® CV3540P-A Black Impression Plus cover ® CV3540P-W-A Gray Impression Plus cover ® CV3107-1 Motor Drive bracket & spring clip CV3002A (Includes #5, #6) CV3579WI...
  • Page 20 REPLACEMENT PARTS PISTON ASSEMBLY Item No. Part No. Description Qty. CV3005 1” spacer stack assembly CV3430 1.25” spacer stack assembly CV3004 Drive cap assembly CV3135 O-ring 228 CV3011 1” piston assembly downflow CV3011-01 1” piston assembly upflow CV3407 1.25” piston assembly downflow NOTE: Optional On Some Models Only.
  • Page 21 REPLACEMENT PARTS BYPASS VALVE Item No. Part No. Description Qty. CV3006 Bypass assembly CV3147 Bypass handles BRINE ELBOW ASSEMBLY Item No. Part No. Description Qty. CV3195-01 Refill port plug assembly CH4615 Elbow locking clip CV4144 3/8” Elbow, Parker fitting CV3163 O-ring 019 Loosens Injector And Bypass Caps...
  • Page 22 REPLACEMENT PARTS INJECTOR ASSEMBLIES Item No. Part No. Description Qty. CV3176 Injector cap CV3152 O-ring 135 CV3177-01 Injector screen CV3010-1Z Injector assembly plug CV3010-1A A injector assembly, BLACK CV3010-1B B injector assembly, BROWN CV3010-1C C injector assembly, VIOLET CV3010-1D D injector assembly, CV3010-1E E injector assembly, WHITE...
  • Page 23 REPLACEMENT PARTS DRAIN LINE ASSEMBLY 3/4” DRAIN LINE ASSEMBLY 1” Item No. Part No. Description Qty. Item No. Part No. Description Qty. CH4615 Elbow locking clip CH4615 Elbow locking clip CPKP10TS8-BULK Optional insert, 5/8” tube CV3166 Drain FTG body 1 CV3192 Optional nut, 3/4”...
  • Page 24 REPLACEMENT PARTS IN/OUT HEAD Item No. Part No. Description Qty. CD1400 1191 In/Out Head 112.4 4.43 IN/OUT HEAD W/FILL PORT Item No. Part No. Description Qty. CD1220-01 1190 In/Out Head W/Port OZONE GENERATOR Item No. Part No. Description Qty. OZ1-A-WR Ozone Kit Assembly F800MAL250VP Fuse...
  • Page 25: Installation Fitting Assemblies

    INSTALLATION FITTING ASSEMBLIES NOTE: Not all available fi ttings are displayed below. Contact manufacturer for optional fi ttings. 1” PVC MALE NPT ELBOW 3/4” & 1” PVC SOLVENT ELBOW Item Item Part No. Description Qty. Part No. Description Qty. CV3007 1”...
  • Page 26 INSTALLATION FITTING ASSEMBLIES NOTE: Not all available fi ttings are displayed below. Contact manufacturer for optional fi ttings. 1-1/4” & 1-1/2” BRASS SWEAT 1-1/4” & 1-1/2” PVC SOLVENT Item Item Part No. Description Qty. Part No. Description Qty. CV3007-09 1-1/4 & 1-1/2” brass sweat assembly CV3007-07 1-1/4”...
  • Page 27: Specifications

    Impression Series Air Filter Specifications IMPRESSION SERIES AIR FILTER SPECIFICATIONS When specifying Impression Plus Series units, use “IMP” prefix in place of “IM” or “IP” in place of “I”. Sulfur and Iron Air Filters IMS-1054 IMS-1248 IMS-1354 IMFE-1054 IMFE-1248 IMFE-1354...
  • Page 28 Impression Series Filter Specifications IMPRESSION SERIES FILTER SPECIFICATIONS When specifying Impression Plus Series units, use “IMP” prefix in place of “IM”. ACID NEUTRALIZERS (IMBF-MAN/IMAN) IMBF-1044MAN IMBF-1054MAN IMBF-1354MAN IMAN-1044 IMAN-1054 IMAN-1354 MODEL IMPBF-1044MAN IMPBF-1054MAN IMPBF-1354MAN IMPAN-1044 IMPAN-1054 IMPAN-1354 Calcite or Mix...
  • Page 29: Warranty

    Water Filter Limited Warranty Congratulations. You have purchased one of the nest water treatment systems available. In the unlikely event of a problem due to defects in material and workmanship, we proudly warrant our water lters to the original owner, when installed in accordance with Water-Right speci cations.
  • Page 30: Quick Reference Guide

    QUICK REFERENCE GUIDE GENERAL OPERATION ERROR When the system is operating, one of four displays will be shown: If the display toggles between “Error” CALL FOR SERVICE 1. time of day/gpm and an error code (i.e. a number), call ERROR 2.
  • Page 31 This page left intentionally blank.
  • Page 32: Water-Right

    1900 Prospect Court • Appleton, WI 54914 © 2018 Water-Right, Inc. All rights reserved. Phone: 920-739-9401 • Fax: 920-739-9406 MAN-IM/IMP FILT RevA0818...

This manual is also suitable for:

Impression plus series

Table of Contents