Advertisement

Impression Series
Impression Plus Series
Water Filters
and
®
®
For Models:
• IMBF
• IMPBF
• IMPBF-MAN
• IMBF-MAN
• IMAN
• IMPAF-MGS
• IMAF-MGS
• IMPS
• IMS
• IMPB
• IMB
• IPAG
• IAG
• IPACG-AN
• IACG-AN

Advertisement

Table of Contents
loading

Summary of Contents for Water Right Impression Series

  • Page 1 Impression Series ® Impression Plus Series ® Water Filters For Models: • IMBF • IMPBF • IMPBF-MAN • IMBF-MAN • IMAN • IMPAF-MGS • IMAF-MGS • IMPS • IMS • IMPB • IMB • IPAG • IAG • IPACG-AN • IACG-AN...
  • Page 2: Table Of Contents

    . Your Impression Series water filters are precision built, high quality products . These units will deliver filtered water for many years to come, when installed and operated properly . Please study this manual carefully and understand the cautions and notes before installing .
  • Page 3: Preinstallation Instructions For Dealers

    PREINSTALLATION INSTRUCTIONS FOR DEALERS: The manufacturer has preset the water treatment unit’s sequence of cycles and cycle times . The dealer should read this page and guide the installer regarding hardness, day override, and time of regeneration, before installation. For the installer, the following must be used: •...
  • Page 4: Bypass Valve

    BYPASS VALVE: The bypass valve is typically used to isolate the control valve from the plumbing system’s water pressure in order to perform control valve repairs or maintenance . The 1” full flow bypass valve incorporates four positions, including a diagnostic position that allows a service technician to have pressure to test a system while providing untreated bypass water to the building .
  • Page 5: Installation

    INSTALLATION: GENERAL INSTALLATION & SERVICE WARNINGS The control valve, fittings and/or bypass are designed to accommodate minor plumbing misalignments . There is a small amount of “give” to properly connect the piping, but the water softener is not designed to support the weight of the plumbing . Do not use Vaseline, oils, other hydrocarbon lubricants or spray silicone anywhere .
  • Page 6 When installing an air regenerating filter the customer may experience, under certain conditions, small amounts of air (cloudy water) at the taps . This is normal . On rare occasions, this may result in “shots of air” at a particular fixture .
  • Page 7 AIR DRAW Screen Elbow 8 . CHECK VALVE: All air systems include an internal check valve and CHECK VALVE screen assembly as part of the air draw system (see diagram at ASSEMBLY right) . This check valve, screen, and elbow are exclusive to the air Air flow system and are not to be confused or interchanged with a brine elbow used on a softener .
  • Page 8: Programming Procedures

    PROGRAMMING PROCEDURES: 1. Set time of day: Time of day should only need to be set after extended power outages or when daylight saving time begins or ends . If an extended power outage occurs, the time of day will flash on and off indicating that the time should be reset . STEP 1 –...
  • Page 9: Startup Instructions

    STARTUP INSTRUCTIONS: FLUSHING OF SYSTEM: To flush the system of any debris and air after installation is complete, please perform the following steps: 1 . Rotate bypass handles to the bypass mode (see Fig. 2 of page 4) . 2 . Turn on inlet water and check for leaks in the newly installed plumbing . 3 .
  • Page 10: Operating Displays And Instructions

    OPERATING DISPLAYS AND INSTRUCTIONS: 1 . GENERAL OPERATION: When the system is operating, one of three GENERAL OPERATION DISPLAYS displays may be shown . Pressing will alternate between the displays . next One of the displays is always the current time of day . The second display shows the current treated water flow rate through the system in Gallons Per Minute .
  • Page 11 5 . ERROR MESSAGE: If the word “ERROR” and a number are alternately ERROR MESSAGE flashing on the display record the number and contact the dealer for help . This indicates that the control valve was not able to function properly . 6 .
  • Page 12: Replacement Mineral Instructions For Acid Neutralizers

    REPLACEMENT MINERAL INSTRUCTIONS FOR ACID NEUTRALIZERS: The IMBF-AN, IMAN and IACG systems raise the pH of mildy acidic water . The raising of pH utilizes a sacrificial mineral that will need replenishment every 6 to 12 months . Typically the media should not be below the halfway point in the tank . In order to check the mineral height and before adding mineral to the system, please follow these instructions .
  • Page 13: Troubleshooting Guide

    TROUBLESHOOTING GUIDE: PROBLEM CAUSE CORRECTION A . No power at electric outlet A . Repair outlet or use working outlet B . Control valve power adapter not plugged into B . Plug power adapter into outlet or connect outlet or power cord end not connected to PC power cord end to PC board connection board connection 1.
  • Page 14 TROUBLESHOOTING GUIDE cont’d: PROBLEM CAUSE CORRECTION A . Turn bypass handles to place bypass in A . Bypass valve in bypass position service position 7. Control valve does not B . Meter is not connected to meter connection on B . Connect meter to three pin connection labeled regenerate automatically PC board METER on PC board...
  • Page 15 PROBLEM CAUSE CORRECTION A . Injector is plugged A . Remove injector and clean or replace B . Faulty regenerant piston B . Replace regenerant piston C . Regenerant line connection leak C . Inspect regenerant line for air leak 12.
  • Page 16 TROUBLESHOOTING GUIDE cont’d: PROBLEM CAUSE CORRECTION A . Check motor connections then Press NEXT and REGEN buttons for 3 seconds to resynchronize A . Motor failure during a regeneration software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect .
  • Page 17: Replacement Parts

    REPLACEMENT PARTS: FRONT COVER AND DRIVE ASSEMBLY Item No. Part No. Description Qty. CV3540-A Black Impression cover ® CV3540-W-A Gray Impression cover ® CV3540P-A Black Impression Plus cover ® CV3540P-W-A Gray Impression Plus cover ® CV3107-1 Motor CV3106-1 Drive bracket & spring clip CV3579WI PC board, CC CV3110...
  • Page 18 REPLACEMENT PARTS: PISTON ASSEMBLY Item No. Part No. Description Qty. CV3005 1” spacer stack assembly CV3430 1 .25” spacer stack assembly CV3004 Drive cap assembly CV3135 O-ring 228 CV3011 1” piston assembly downflow CV3011-01 1” piston assembly upflow CV3407 1 .25” piston assembly downflow NOTE: For Impression Plus ®...
  • Page 19 REPLACEMENT PARTS: BYPASS VALVE Item No. Part No. Description Qty. CV3151 Nut, 1” quick connect CV3150 Split ring CV3105 O-ring 215 CV3145 Bypass rotor, 1” CV3146 Bypass cap CV3147 Bypass handle CV3148 Bypass rotor seal retainer CV3152 O-ring 135 CV3155 O-ring 112 CV3156 O-ring 214...
  • Page 20 REPLACEMENT PARTS: INJECTOR ASSEMBLIES Item No. Part No. Description Qty. CV3176 Injector cap CV3152 O-ring 135 CV3177-01 Injector screen CV3010-1Z Injector assembly plug A injector assembly, CV3010-1A black CV3010-1B B injector assembly, brown CV3010-1C C injector assembly, violet CV3010-1D D injector assembly, E injector assembly, CV3010-1E white...
  • Page 21 REPLACEMENT PARTS: DRAIN LINE ASSEMBLY 3/4” Item No. Part No. Description Qty. CH4615 Elbow locking clip CPKP10TS8-BULK Optional insert, 5/8” tube CV3192 Optional nut, 3/4” drain elbow CV3158-01 Drain elbow, 3/4” NPT with O-ring CV3163 O-ring 019 CV3159-01 DLFC retainer assembly CV3162-007 0 .7 DLFC for 3/4”...
  • Page 22 REPLACEMENT PARTS: CHLORINE TANK ASSEMBLY Item No. Part No. Description Qty. CH4600-50 474 safety float valve CH4640-32 474 float assembly CH4500-48 474 air check CN1043 10” pad for feeder CH7001 Grid for feeder SERVICE WRENCH - CV3193-02 Although no tools are necessary to assemble or disassemble the valve, the Service Wrench, (shown in various positions on the valve) is available to aid in assembly or disassembly .
  • Page 23 INSTALLATION FITTING ASSEMBLIES: 1” PVC MALE NPT ELBOW 3/4” & 1” PVC SOLVENT ELBOW Item Item Part No. Description Qty. Part No. Description Qty. CV3007 1” PVC male NPT elbow assembly CV3007-01 3/4” & 1” PVC solvent elbow assembly CV3151 Nut, 1”...
  • Page 24 INSTALLATION FITTING ASSEMBLIES: 1-1/4” & 1-1/2” BRASS SWEAT 1-1/4” & 1-1/2” PVC SOLVENT Item Item Part No. Description Qty. Part No. Description Qty. CV3007-09 1-1/4 & 1-1/2” brass sweat assembly CV3007-07 1-1/4” & 1-1/2” PVC solvent assembly CV3151 Nut, 1” quick connect CV3151 Nut, 1”...
  • Page 25: Specifications

    IMPRESSION SERIES FILTER SPECIFICATIONS: When specifying Impression Plus Series units, use “IMP” prefix in place of “IM”. ACID NEUTRALIZERS MODEL NUMBER IMBF-1044MAN IMBF-1054MAN IMBF-1354MAN IMAN-1044 IMAN-1054 IMAN-1354 Mineral Type Calcite or Mix Calcite or Mix Calcite or Mix Calcite or Mix...
  • Page 26: Specifications

    IMPRESSION SERIES AIR FILTER SPECIFICATIONS: When specifying Impression Plus Series units, use “IMP” prefix in place of “IM” or “IP” in place of “I”. SULFUR AND IRON AIR FILTERS MODEL NUMBER IMS-1054 IMS-1248 IMS-1354 IMB-1054 IMB-1248 IMB-1354 Mineral Type Catalytic Carbon...
  • Page 27: Warranty

    Water Conditioner Limited Warranty Congratulations. You have purchased one of the finest water treatment systems available. In the unlikely event of a problem due to defects in material and workmanship, we proudly warrant our water conditioners to the original owner, when installed in accordance with Water-Right specifications.
  • Page 28: Quick Reference Guide

    QUICK REFERENCE GUIDE: GENERAL OPERATION When the system is operating, MANUAL one of three displays will be REGENERATION shown: time of day, gallons of NOTE: If you need treated water available, or gallons per minute . to initiate a manual Pressing will regeneration, either immediately, or the...

Table of Contents