Interface Connectors; 10Base2; 10Baset; Aui - Xycom XVME-976 Manual

Adapter module
Hide thumbs Also See for XVME-976:
Table of Contents

Advertisement

XVME-976 Adapter Module

Interface Connectors

The paragraphs below describe connectors 10BASE2, 10BASET, and AUI.

10BASE2

When the BNC connector is used, a BNC TEE must be connected to the XVME-
956/411's BNC connector if the Ethernet coax does not end at the XVME-956/411.
If the coax ends at the XVME-956/411, a 50 Ohm terminator must be installed. This
terminator can be a BNC terminator if the BNC TEE is used or the internal XVME-
956/411 termination option can be used.

10BASET

When twisted pair networks are used, a 10BaseT hub must be supplied. You cannot
simply connect from one interface card to another when twisted pair is used.

AUI

This connector is provided to external transceivers. This connector is a female D-
SUB connector with a pinout that matches the AUI standard pinout. 12 V power on
the AUI connector is directly connected to the PC/104 bus 12 V system power.