Setting The Inactivity Timer (For Procedures On Hold) - JRC JHS-800S Instruction Manual

Marine vhf radiotelephone
Hide thumbs Also See for JHS-800S:
Table of Contents

Advertisement

Settings & Registrations
5.5.6

Setting the inactivity timer (for procedures on hold)

W hen making a procedure on hold, the procedure is automatically terminated after the time set as
follows.
Procedure
1 1
. .
1
.
Touch the [INACTV T/O] button.
2 2
. .
2
.
Display the transmission category you want to set
with the [↑]/[↓] buttons, and then make changes using
either the [+]/[-] buttons or the [Edit] button.
➢ The setting items are as follows.
ACK DIST:
RCV DIST:
NON DIST:
OTHER COMM: Communications without using DSC .
3 3
. .
3
.
Finally, touch the [ ✓ ] button to register.
5-15
The acknowledged distress alert events
sent from the own ship .
(Setting range: 00 (OFF) to 60 minutes)
The distress events of other ships .
(Setting range: 00 (OFF) to 60 minutes)
Routine, safety and urgency events .
(Setting range: 00 (OFF) to 60 minutes)
(Setting range: 010 to 600 seconds; this timer cannot be set to OFF.)