5. Turn on power to the KPM(T) monitor, and then to the host computer. The
system will boot up the installed operating system.
6. Install the application software via a floppy drive, CD-ROM, or the network.
Additional aspects to take into account when mounting your KPM(T) monitor:
Consider locations of accessories such as AC power outlets and lighting
• • • •
(interior lighting and windows) for installation and maintenance convenience
Prevent condensation by installing a thermostat-controlled heater or air
• • • •
conditioner
To allow for maximum cooling, avoid obstructing the airflow
• • • •
Place any fans or blowers close to the heat generating devices. If using a fan,
• • • •
make sure that outside air is not brought into the enclosure unless a fabric or
other reliable filter is used. This filtration prevents conductive particles and
other harmful contaminants from entering the enclosure.
Do not select a location near equipment that generates excessive
• • • •
electromagnetic interference (EMI) or radio frequency interface (RFI).
Examples of these types of equipment are: high power welding machines;
induction heating equipment; and large motor starters.
Place incoming power line devices (such as isolation or constant voltage
• • • •
transformers, local power disconnects, and surge suppressers) away from the
system. The proper location of incoming line devices keeps power wire runs
as short as possible and minimizes electrical noise transmitted to the unit.
Make sure the location does not exceed the unit's shock, vibration, and
• • • •
temperature specifications
Install the unit in the rack or panel in such a way as to ensure that it does not
• • • •
cause a hazard from uneven mechanical loading
Incorporate a readily-accessible disconnect device in the fixed wiring on
• • • •
permanently connected equipment
Avoid circuit overloading of the supply circuit
• • • •