  • Page 1: Hardware Guide

    VT1040 FLAT PANEL INDUSTRIAL MONITOR INDUSTR Hardware Guide...
  • Page 2 Xycom Automation Part Number 301040/141283(E) Trademark Information Xycom Automation is a trademark of Xycom Automation, Inc. Brand or product names may be registered trademarks of their respective owners. Windows is a registered trademark of Microsoft Corporation in the United States and other countries.
  • Page 3: Table Of Contents

    Table of Contents 1. Product Overview....................1 Product Features……………………...…………………………………………………………1 Standard VT1040 Features…………………………………………………………………….1 Parts List……………………………...…………………………………………………………1 Standard VT1040 Parts List…………………………………………………………………...1 Manual Overview………………………………………………………………………………..2 Text Conventions Used in this Manual ...………………………………………………………2 Product Dimensions …………………………………………………………………………….3 Front Panel Controls …………………………………………….……………………………3 Product Specifications and Ratings……..………………………………………………………4 Environmental…………………………………………………………………………………4 Electrical ……………………………………………………………………………………...4 Front Panel/Enclosure ..…….…..……………………….…………………………………..4...
  • Page 4: Product Overview

    Units ship with all necessary cables and software • Parts List When you remove the VT1040 from its shipping carton, verify that you have the parts listed below. Save the box and inner wrapping in case you need to reship the unit. Standard VT1040 Parts List •...
  • Page 5: Manual Overview

    Manual Overview The manual is divided in the following chapters: • Chapter 1 – Product Overview • Chapter 2 – Installation • Chapter 3 – Monitor Settings Chapter 4 – Hardware • Text Conventions Used in this Manual Throughout this manual, certain terms are formatted in ways that indicate what type of object is being described.
  • Page 6: Product Dimensions

    Product Dimensions 10.50[266.70] 12.60[320.04] 3.00[76.20] in.[mm] Front Panel Controls The front panel controls, from left to right are Menu, Select, Increment, Decrement. Their use is detailed in Chapter 3— Monitor Settings. 141283 (E)
  • Page 7: Product Specifications And Ratings

    Product Specifications and Ratings Environmental Operating Nonoperating Thermal 0°C to 50°C (32°F to 122°F) -20° C to 60° C (32° F to 122° F) Humidity 20% to 80% RH, noncondensing 20% to 80% RH, noncondensing 15 g peak acceleration, 30 g peak acceleration, Shock 11 msec duration 11 msec duration...
  • Page 8: Installation

    2. Installation Environmental Considerations The rugged design of the VT1040 allows it to be installed in most industrial environments. Refer to the electrical and environmental specifications and tolerances (pg. 4) for more detailed information. System Power It is a good practice to use isolation transformers on the incoming AC power line to the system.
  • Page 9: Electrical Noise

    Electrical Noise Electrical noise is seldom responsible for damaging components, unless extremely high energy or high voltage levels are present. However, noise can cause temporary malfunctions that can result in hazardous machine operation in certain applications. Noise may be present only at certain times, may appear at widely spread intervals, or in some cases may exist continuously.
  • Page 10: Panel Mounting Dimensions

    reliable filter is used. This filtration prevents conductive particles or other harmful contaminants from entering the enclosure. • Do not select a location near equipment that generates excessive electromagnetic interference (EMI) or radio frequency interface (RFI) (equipment such as high-power welding machines, induction heating equipment, and large motor starters).
  • Page 11: Monitor Settings

    Not all video controllers produce exactly the same video output levels or the same timing. The VT1040 uses onscreen programming to make setup and adjustment easy. The menus are selected and the menu items are adjusted using the buttons located on the monitor front panel.
  • Page 12: Onscreen Display (Osd) Functions

    Onscreen Display (OSD) Functions Front Panel Controls The front panel controls, from left to right are Menu, Select, Increment, Decrement and Power. Menu: This button opens and closes menu screens. This button will perform the menu command labeled number one. Select: This button selects the highlighted menu item.
  • Page 13: Rgb Submenu

    RGB Submenu Menu Option Description Increase/decrease red color level: Press Increment or Decrement to adjust; range is 0 to 127. Green Increase/decrease green color level: Press Increment or Decrement to adjust; range is 0 to 127. Blue Increase/decrease blue color level: Press Increment or Decrement to adjust;...
  • Page 14: Installing The Touch Screen Driver

    Installing the Touch Screen Driver If your Xycom flat panel monitor has the touch screen option, you will have to load the correct touch screen driver on the computer to which you will be connecting the monitor. The following steps should be performed on that computer.
  • Page 15: Hardware

    After 50,000 hours of use, the two lamps used for LCD back lighting may become dim or burn out. You may return the monitor to Xycom for lamp replacement or you can order new lamps and follow the procedure below to install them. You can perform the lamp replacement procedure without removing the monitor from the NEMA enclosure where it is mounted, but you should do this only in a clean environment.
  • Page 16 Reconnect the lamp wires to the inverter. These are keyed connectors permitting insertion in only one orientation. You may now want to clean the LCD and the inside of the monitor window or touchscreen with a slightly damp soft cloth. Carefully reunite the two monitor halves remembering to reconnect the touchscreen cable if the unit is so equipped.
  • Page 17: Appendix A: Reaching Technical Support

    5. Details of attempts made to rectify the problem(s) and results. 6. The log number assigned from Xycom Automation Technical Support if this is an ongoing problem. 7. The name of the Technical Support Engineer with whom you last spoke, if known.