3.8. Remove the heater tank and the inlet connector assembly from the flow valve
and switch assembly.
3.9. Remove the microswitches from the flow valve and switch assembly.
3.10. Make a note of the positions of the solenoid wires on top of the heater tank.
Remove the solenoid wires.
3.11. Remove the flow valve and switch assembly.
3.12. Refit the components in reverse order. Make sure that the electrical wires are
installed in the correct positions.
Terminal Block
15mm compression
straight connector
(not supplied)
Inlet Supply
Pipe
Inlet Connector
Flow Valve and Switch Assembly - Removal and Installation
20
Microswitch
Clamp Bracket
Clamp Bracket
Retaining Screws
Splash Guard
Microswitch
Switch
Assembly
Outlet Connector
Flow Valve
Heater
Tank
Heater Tank
Retaining
Screws