Installation Manual
CAUTION
Do not allow children to play on or around the unit or it
may result in injury.
may result in injury if improperly used. To avoid injury wear
Do not touch the refrigerant pipes during and immediately
after operation as the refrigerant pipes may be hot or
ing through the refrigerant piping, compressor, and other
refrigerant cycle parts. It may result in your hands get-
ting burns or frostbite if you touch the refrigerant pipes.
To avoid injury, give the pipes time to return to normal
temperature or, if you must touch them, be sure to wear
proper gloves.
Install drain piping to proper drainage. Improper drain pip-
ing may result in water leakage and property damage.
Insulate piping to prevent condensation.
Be careful when transporting the product.
Do not turn off the power immediately after stopping
operation. Always wait for at least 5 minutes before turning
off the power. Otherwise, water leakage may result.
Do not use a charging cylinder. Using a charging cylinder
may cause the refrigerant to deteriorate.
Refrigerant R410A in the system must be kept clean, dry,
and tight.
(a) Clean and Dry - Foreign materials (including mineral
oils such as SUNISO oil or moisture) should be pre-
vented from getting into the system.
(b) Tight - R410A does not contain any chlorine, does
not destroy the ozone layer, and does not reduce the
earth's protection again harmful ultraviolet radiation.
R410A can contribute to the greenhouse effect if it is
released. Therefore take proper measures to check
for the tightness of the refrigerant piping installation.
Read the chapter Refrigerant Piping and follow the
procedures.
Since R410A is a blend, the required additional refriger-
ant must be charged in its liquid state. If the refrigerant is
charged in a state of gas, its composition can change and
the system will not work properly.
The indoor unit is for R410A. See the catalog for indoor
models that can be connected. Normal operation is not
possible when connected to other units.
Remote controller (wireless kit) transmitting distance can
cent lamps (inverter or rapid start types). Install the indoor
Indoor units are for indoor installation only. Outdoor units
can be installed either outdoors or indoors. This unit is for
indoor use.
Do not install the air conditioner or heat pump in the fol-
lowing locations:
(a) Where a mineral oil mist or oil spray or vapor is pro-
Plastic parts may deteriorate and fall off and thus may
result in water leakage.
(b) Where corrosive gas, such as sulfurous acid gas, is
produced.
Corroding copper pipes or soldered parts may result
in refrigerant leakage.
3P362438-1B English
10
(c) Near machinery emitting electromagnetic waves.
the control system and cause the unit to malfunction.
(d)
are handled. Operating the unit in such conditions
Take adequate measures to prevent the outdoor unit from
being used as a shelter by small animals. Small animals
making contact with electrical parts may result in malfunc-
-
area around the unit clean.
NOTE
Install the power supply and transmission wires for the in-
visions or radios to prevent image interference or noise.
Dismantling the unit, treatment of the refrigerant, oil and
additional parts must be done in accordance with the
relevant local, state, and national regulations.
Do not use the following tools that are used with con-
ventional refrigerants: gauge manifold, charge hose, gas
base, vacuum gauge, or refrigerant recovery equipment.
If the conventional refrigerant and refrigerator oil are
This air conditioner or heat pump is an appliance that
should not be accessible to the general public.
As design pressure is 478 psi (3.3 MPa), the wall thick-
dance with the relevant local, state, and national regula-
tions.
Codes and Regulations
This product is designed and manufactured to comply with
national codes. Installation in accordance with such codes
and/or prevailing local codes/regulations is the responsibility
of the installer. The manufacturer assumes no responsibility
for equipment installed in violation of any codes or regula-
tions. Rated performance is achieved after 72 hours of opera-
tion.
-
EDUS341411-N
-
-
-
ii
3P362438-1B
Installation of Outdoor Units