Aqua Lung S.E.A. LV-2 Technical Manual page 11

Survival egress air
Table of Contents

Advertisement

5. Gently grasp the lever and remove the entire valve
assembly (44-51) from the box bottom (63). It may be
necessary to push in on the valve assembly through the
inlet hole into the box bottom (63).
CAUTION:
Valve assembly parts are under spring pressure.
When removing the locknut (44), be sure to keep the poppet
side of the valve assembly against the work surface or place
a finger over the poppet to prevent the parts from ejecting
from the valve body (46).
6. Hold the valve assembly, poppet side facing down, firmly
against the work surface. Using a 1/4" nut driver, remove the
locknut (44) and discard. Separate the locknut, washer (46),
lever (45), poppet (50), and spring (49) from the valve body
(47). Using the threaded end of the poppet, press the poppet
bearing (48) out of the valve body and discard.
7. Using your fingers, unscrew the exhaust cover (65).
50
49
47
45
46
44
8. Remove the exhaust valve (64) by grasping the flap of the
valve and pulling straight outward. Discard exhaust valve.
9. Using the tip of the o-ring tool (p/n 944022), or any type
of pointed tip type tool, pierce the center of the LP seat (51)
and remove it from the poppet. DO NOT discard the seat, as
it will be used later to aid in reassembly.
ThiS EnDS DiSaSSEMBly
Before starting reassembly, perform partsclean-
ing and lubrication in accordance with
Procedure A: Cleaning and Lubricating, p. 30.